TY - JOUR
T1 - Efficacy on resynchronization and longitudinal contractile function comparing His-bundle pacing with conventional biventricular pacing
T2 - a substudy to the His-alternative study
AU - Højgaard, E V
AU - Philbert, B T
AU - Linde, J J
AU - Winsløw, U C
AU - Svendsen, J H
AU - Vinther, M
AU - Risum, N
N1 - © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. All rights reserved. For permissions, please e-mail: [email protected].
PY - 2023/12/21
Y1 - 2023/12/21
N2 - AIMS: His-bundle pacing has emerged as a novel method to deliver cardiac resynchronization therapy (CRT). However, there are no data comparing conventional biventricular (BiV)-CRT with His-CRT with regard to effects on mechanical dyssynchrony and longitudinal contractile function.METHODS AND RESULTS: Patients with symptomatic heart failure, left ventricular ejection fraction ≤ 35%, and left bundle branch block (LBBB) by strict ECG criteria were randomized 1:1 to His-CRT or BiV-CRT. Two-dimensional strain echocardiography was performed prior to CRT implantation and at 6 months after implantation. Differences in changes in mechanical dyssynchrony (standard deviation of time-to-peak in 12 midventricular and basal segments) and regional longitudinal strain in the six left ventricular walls were compared between the BiV-CRT and His-CRT groups.In the on-treatment analysis, 31 received BiV-CRT and 19 His-CRT. In both groups, mechanical dyssynchrony was significantly reduced after 6 months [BiV group from 120 ms (±45) to 63 ms (±22), P < 0.001, and His group from 116 ms (±54) to 49 ms (±11), P < 0.001] but no significant differences in changes could be demonstrated between groups [-9.0 ms (-36; 18), P = 0.50]. Global longitudinal strain (GLS) improved in both groups [BiV group from -9.1% (±2.7) to -10.7% (±2.6), P = 0.02, and His group from -8.6% (±2.1) to -11.1% (±2.0), P < 0.001], but no significant differences in changes could be demonstrated from baseline to follow-up [-0.9% (-2.4; -0.6), P = 0.25] between groups. There were no regional differences between groups.CONCLUSION: In heart failure, patients with LBBB, BiV-CRT, and His-CRT have comparable effects with regard to improvements in mechanical dyssynchrony and longitudinal contractile function.
AB - AIMS: His-bundle pacing has emerged as a novel method to deliver cardiac resynchronization therapy (CRT). However, there are no data comparing conventional biventricular (BiV)-CRT with His-CRT with regard to effects on mechanical dyssynchrony and longitudinal contractile function.METHODS AND RESULTS: Patients with symptomatic heart failure, left ventricular ejection fraction ≤ 35%, and left bundle branch block (LBBB) by strict ECG criteria were randomized 1:1 to His-CRT or BiV-CRT. Two-dimensional strain echocardiography was performed prior to CRT implantation and at 6 months after implantation. Differences in changes in mechanical dyssynchrony (standard deviation of time-to-peak in 12 midventricular and basal segments) and regional longitudinal strain in the six left ventricular walls were compared between the BiV-CRT and His-CRT groups.In the on-treatment analysis, 31 received BiV-CRT and 19 His-CRT. In both groups, mechanical dyssynchrony was significantly reduced after 6 months [BiV group from 120 ms (±45) to 63 ms (±22), P < 0.001, and His group from 116 ms (±54) to 49 ms (±11), P < 0.001] but no significant differences in changes could be demonstrated between groups [-9.0 ms (-36; 18), P = 0.50]. Global longitudinal strain (GLS) improved in both groups [BiV group from -9.1% (±2.7) to -10.7% (±2.6), P = 0.02, and His group from -8.6% (±2.1) to -11.1% (±2.0), P < 0.001], but no significant differences in changes could be demonstrated from baseline to follow-up [-0.9% (-2.4; -0.6), P = 0.25] between groups. There were no regional differences between groups.CONCLUSION: In heart failure, patients with LBBB, BiV-CRT, and His-CRT have comparable effects with regard to improvements in mechanical dyssynchrony and longitudinal contractile function.
KW - Arrhythmias, Cardiac/therapy
KW - Bundle-Branch Block/diagnostic imaging
KW - Cardiac Resynchronization Therapy/methods
KW - Electrocardiography/methods
KW - Heart Failure/diagnostic imaging
KW - Humans
KW - Stroke Volume
KW - Treatment Outcome
KW - Ventricular Function, Left
UR - http://www.scopus.com/inward/record.url?scp=85181178052&partnerID=8YFLogxK
U2 - 10.1093/ehjci/jead181
DO - 10.1093/ehjci/jead181
M3 - Journal article
C2 - 37490036
SN - 1525-2167
VL - 25
SP - 66
EP - 74
JO - European Heart Journal Cardiovascular Imaging
JF - European Heart Journal Cardiovascular Imaging
IS - 1
ER -