Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Effect of increasing pump speed during exercise on peak oxygen uptake in heart failure patients supported with a continuous-flow left ventricular assist device. A double-blind randomized study

Research output: Contribution to journalJournal articleResearchpeer-review

DOI

  1. Hypertensive disorders in women with peripartum cardiomyopathy: insights from the ESC EORP PPCM Registry

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Recovery of Cardiac Function Following COVID-19 - ECHOVID-19: A Prospective Longitudinal Cohort Study

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Urinary peptides in heart failure: a link to molecular pathophysiology

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

AIMS: Continuous-flow left ventricular assist device (CF-LVAD) implantation is associated with improved quality of life, but the effect on exercise capacity is less well documented. It is uncertain whether a fixed CF-LVAD pump speed, which allows for sufficient circulatory support at rest, remains adequate during exercise. The aim of this study was to evaluate the effects of fixed versus incremental pump speed on peak oxygen uptake (peak VO2) during a maximal exercise test.

METHODS AND RESULTS: In CF-LVAD (HeartMate II) patients exercise testing measuring peak oxygen uptake (VO2) was performed on an ergometer bike twice in one day: once with fixed pump speed (testfix) and once with incremental pump speed (testinc). The order of testfix and testinc in each patient was determined by randomization. During testinc pump speed was increased from the baseline value by 400 rpm/2 min. Fourteen patients (aged 23–69 years) were included with a mean support duration of 465±483 days. Baseline CF-LVAD speed was 9357±238 rpm and during testinc speed was increased by a mean of 1486±775 rpm. Mean peak VO2 was significantly higher in testinc compared with testfix (15.4±5.9 mL/kg/min vs. 14.1±6.3 mL/kg/min; P=0.012), corresponding to a 9.2% increase. All exercise tests (n=28) were adequately performed with RER>1.

CONCLUSION: Increasing pump speed during exercise augments peak VO2 in patients supported with CF-LVADs. An automatic speed-change function in future generations of CF-LVADs might improve functional capacity.

Original languageEnglish
JournalEuropean Journal of Heart Failure
Volume16
Issue number4
Pages (from-to)403-8
Number of pages6
ISSN1388-9842
DOIs
Publication statusPublished - Apr 2014

ID: 45016831