TY - JOUR
T1 - Effect of Implantable Cardioverter-defibrillators in Nonischemic Heart Failure According to Background Medical Therapy
T2 - Extended follow-up of the DANISH trial
AU - Yafasova, Adelina
AU - Doi, Seiko N
AU - Thune, Jens Jakob
AU - Nielsen, Jens C
AU - Haarbo, Jens
AU - Bruun, Niels E
AU - Gustafsson, Finn
AU - Eiskjær, Hans
AU - Hassager, Christian
AU - Svendsen, Jesper H
AU - Høfsten, Dan E
AU - Torp-Pedersen, Christian
AU - Pehrson, Steen
AU - Køber, Lars
AU - Butt, Jawad H
N1 - Copyright © 2024. Published by Elsevier Inc.
PY - 2024/5/13
Y1 - 2024/5/13
N2 - BACKGROUND: The Heart Failure Collaboratory (HFC) score integrates types and dosages of guideline-directed pharmacotherapies for heart failure (HF) with reduced ejection fraction (HFrEF). We examined the effects of cardioverter-defibrillator (ICD) implantation according to the modified HFC (mHFC) score in 1116 patients with nonischemic HFrEF from the Danish Study to Assess the Efficacy of ICDs in Patients with Nonischemic Systolic HF on Mortality (DANISH).METHODS AND RESULTS: Patients were assigned scores for renin-angiotensin-system inhibitors, beta-blockers and mineralocorticoid receptor antagonists (0, no use; 1, < 50% of maximum dosage; 2, ≥ 50% of maximum dosage). The maximum score was 6, corresponding to ≥ 50% of maximum dosage for all therapies. The median baseline mHFC score was 4, and the median follow-up was 9.5 years. Compared with an mHFC score of 3-4, an mHFC score of 1-2 was associated with a higher rate of all-cause death (mHFC = 1-2: adjusted HR 1.67 [95% CI, 1.23-2.28]; mHFC = 3-4, reference; mHFC = 5-6: adjusted HR 1.07 [95% CI, 0.87-1.31]). ICD implantation did not reduce all-cause death compared with control (reference) (HR 0.89 [95% CI, 0.74-1.08]), regardless of mHFC score (mHFC = 1-2: HR 0.98 [95% CI, 0.56-1.71]; mHFC = 3-4: HR 0.89 [95% CI,0.66-1.20]; mHFC = 5-6: HR 0.85 [95% CI, 0.64-1.12]; Pinteraction, 0.65). Similarly, ICD implantation did not reduce cardiovascular death (HR 0.87 [95% CI, 0.70-1.09]), regardless of mHFC score (Pinteraction, 0.59). The ICD group had a lower rate of sudden cardiovascular death (HR, 0.60 [95% CI,0.40-0.92]); this association was not modified by mHFC score (Pinteraction, 0.35).CONCLUSIONS: Lower mHFC scores were associated with higher rates of all-cause death. ICD implantation did not result in an overall survival benefit in patients with nonischemic HFrEF, regardless of mHFC score.
AB - BACKGROUND: The Heart Failure Collaboratory (HFC) score integrates types and dosages of guideline-directed pharmacotherapies for heart failure (HF) with reduced ejection fraction (HFrEF). We examined the effects of cardioverter-defibrillator (ICD) implantation according to the modified HFC (mHFC) score in 1116 patients with nonischemic HFrEF from the Danish Study to Assess the Efficacy of ICDs in Patients with Nonischemic Systolic HF on Mortality (DANISH).METHODS AND RESULTS: Patients were assigned scores for renin-angiotensin-system inhibitors, beta-blockers and mineralocorticoid receptor antagonists (0, no use; 1, < 50% of maximum dosage; 2, ≥ 50% of maximum dosage). The maximum score was 6, corresponding to ≥ 50% of maximum dosage for all therapies. The median baseline mHFC score was 4, and the median follow-up was 9.5 years. Compared with an mHFC score of 3-4, an mHFC score of 1-2 was associated with a higher rate of all-cause death (mHFC = 1-2: adjusted HR 1.67 [95% CI, 1.23-2.28]; mHFC = 3-4, reference; mHFC = 5-6: adjusted HR 1.07 [95% CI, 0.87-1.31]). ICD implantation did not reduce all-cause death compared with control (reference) (HR 0.89 [95% CI, 0.74-1.08]), regardless of mHFC score (mHFC = 1-2: HR 0.98 [95% CI, 0.56-1.71]; mHFC = 3-4: HR 0.89 [95% CI,0.66-1.20]; mHFC = 5-6: HR 0.85 [95% CI, 0.64-1.12]; Pinteraction, 0.65). Similarly, ICD implantation did not reduce cardiovascular death (HR 0.87 [95% CI, 0.70-1.09]), regardless of mHFC score (Pinteraction, 0.59). The ICD group had a lower rate of sudden cardiovascular death (HR, 0.60 [95% CI,0.40-0.92]); this association was not modified by mHFC score (Pinteraction, 0.35).CONCLUSIONS: Lower mHFC scores were associated with higher rates of all-cause death. ICD implantation did not result in an overall survival benefit in patients with nonischemic HFrEF, regardless of mHFC score.
KW - DANISH
KW - Implantable cardioverter-defibrillator
KW - nonischemic heart failure
KW - pharmacotherapy
UR - http://www.scopus.com/inward/record.url?scp=85193975483&partnerID=8YFLogxK
U2 - 10.1016/j.cardfail.2024.04.017
DO - 10.1016/j.cardfail.2024.04.017
M3 - Journal article
C2 - 38750689
SN - 1071-9164
JO - Journal of Cardiac Failure
JF - Journal of Cardiac Failure
ER -