TY - JOUR
T1 - Dynamic LED light versus static LED light for depressed inpatients
T2 - results from a randomized feasibility trial
AU - Volf, Carlo
AU - Aggestrup, Anne Sofie
AU - Svendsen, Signe Dunker
AU - Hansen, Torben Skov
AU - Petersen, Paul Michael
AU - Dam-Hansen, Carsten
AU - Knorr, Ulla
AU - Petersen, Ema Erkocevic
AU - Engstrøm, Janus
AU - Hageman, Ida
AU - Jakobsen, Janus Christian
AU - Martiny, Klaus
N1 - © The Author(s). 2020.
PY - 2020
Y1 - 2020
N2 - Background: Retrospective studies conducted in psychiatric wards have indicated a shorter duration of stay for depressed inpatients in bright compared to dim daylight-exposed rooms, pointing to a possible antidepressant effect of daylight conditions. Dynamic LED lighting, aiming to mimic daylight conditions, are currently been installed in several hospitals, but their feasibility is poorly investigated.Methods: To investigate the feasibility of these systems, we developed and installed a LED-lighting system in four rooms in a psychiatric inpatient ward. The system could function statically or dynamically regarding light intensity and colour temperature. The system consisted of (A) a large LED luminaire built into the window jamb mimicking sunlight reflections, (B) two LED light luminaires in the ceiling and (C) a LED reading luminaire. In the static mode, the systems provided constant light from A and B. In the dynamic mode, the system changed light intensity and colour temperature using A, B and C. Patients with unipolar or bipolar depression were randomised to dynamic or static LED lighting for 4 weeks, in addition to standard treatment. Primary outcome was the rate of patients discontinuing the trial due to discomfort from the lighting condition. Secondary outcomes were recruitment and dropout rates, visual comfort, depressive symptoms and suicidal ideation.Results: No participants discontinued due to discomfort from the LED lighting. Recruitment rate was 39.8%, dropout from treatment rates were 56.3% in the dynamic group and 33.3% in the static group. 78.1% in the dynamic group were satisfied with the lighting compared with 71.8% in the static group. Discomfort from the light (glare) was reported by 11.5% in the dynamic group compared to 5.1% in the static group. Endpoint suicidal scores were 16.8 (10.4) in the dynamic and 16.3 (14.9) in the static group. The lighting system was 100% functional. The light sensor system proved unstable.Conclusion: Dropout from treatment was high primarily due to early discharge and with a lack of endpoint assessments. The feasibility study has influenced an upcoming large-scale dynamic lighting efficacy trial where we will use a shorter study period of 3 weeks and with more emphasis on endpoint assessments. The lighting was well tolerated in both groups, but some found intensity too low in the evening. Thus, we will use higher intensity blue-enriched light in the morning and higher intensity amber (blue-depleted) light in the evening in the upcoming study. The light sensor system needs to be improved.Trial registration: ClinicalTrials.gov: NCT03363529.
AB - Background: Retrospective studies conducted in psychiatric wards have indicated a shorter duration of stay for depressed inpatients in bright compared to dim daylight-exposed rooms, pointing to a possible antidepressant effect of daylight conditions. Dynamic LED lighting, aiming to mimic daylight conditions, are currently been installed in several hospitals, but their feasibility is poorly investigated.Methods: To investigate the feasibility of these systems, we developed and installed a LED-lighting system in four rooms in a psychiatric inpatient ward. The system could function statically or dynamically regarding light intensity and colour temperature. The system consisted of (A) a large LED luminaire built into the window jamb mimicking sunlight reflections, (B) two LED light luminaires in the ceiling and (C) a LED reading luminaire. In the static mode, the systems provided constant light from A and B. In the dynamic mode, the system changed light intensity and colour temperature using A, B and C. Patients with unipolar or bipolar depression were randomised to dynamic or static LED lighting for 4 weeks, in addition to standard treatment. Primary outcome was the rate of patients discontinuing the trial due to discomfort from the lighting condition. Secondary outcomes were recruitment and dropout rates, visual comfort, depressive symptoms and suicidal ideation.Results: No participants discontinued due to discomfort from the LED lighting. Recruitment rate was 39.8%, dropout from treatment rates were 56.3% in the dynamic group and 33.3% in the static group. 78.1% in the dynamic group were satisfied with the lighting compared with 71.8% in the static group. Discomfort from the light (glare) was reported by 11.5% in the dynamic group compared to 5.1% in the static group. Endpoint suicidal scores were 16.8 (10.4) in the dynamic and 16.3 (14.9) in the static group. The lighting system was 100% functional. The light sensor system proved unstable.Conclusion: Dropout from treatment was high primarily due to early discharge and with a lack of endpoint assessments. The feasibility study has influenced an upcoming large-scale dynamic lighting efficacy trial where we will use a shorter study period of 3 weeks and with more emphasis on endpoint assessments. The lighting was well tolerated in both groups, but some found intensity too low in the evening. Thus, we will use higher intensity blue-enriched light in the morning and higher intensity amber (blue-depleted) light in the evening in the upcoming study. The light sensor system needs to be improved.Trial registration: ClinicalTrials.gov: NCT03363529.
KW - Architecture
KW - Bipolar disorder
KW - Chronotherapy
KW - Circadian
KW - Depression
KW - Hospitals
KW - Light
KW - Lighting
KW - Major depressive disorder
KW - Randomisation
KW - RCT
KW - Sleep
U2 - 10.1186/s40814-019-0548-9
DO - 10.1186/s40814-019-0548-9
M3 - Journal article
C2 - 31956421
SN - 2055-5784
VL - 6
SP - 5
JO - Pilot and Feasibility Studies
JF - Pilot and Feasibility Studies
ER -