Skip to main navigation Skip to search Skip to main content

Diagnostic accuracy and safety of semirigid thoracoscopy in exudative pleural effusions in Denmark

Fatin Willendrup, Uffe Bodtger, Sara Colella, Daniel Rasmussen, Paul F Clementsen

14 Citations (Scopus)

Abstract

BACKGROUND: To assess the diagnostic accuracy and the safety of medical thoracoscopy (MT) performed with the semirigid thoracoscope.

METHODS: We retrospectively evaluated patients who underwent MT with semirigid thoracoscope under local anesthesia for unexplained exudative pleural effusion from March 1, 2009 to September 1, 2013 in Denmark.

RESULTS: Sixty-nine patients were retrospectively studied. In 13 patients it was not possible to perform the scheduled MT, in 9 cases due to an insufficient pneumothorax, in 3 due to an insufficient pleural effusion, and in 1 due to a purulent pleuritis. In 56 patients in whom MT was completed, the procedure was diagnostic in 44 cases: malignancy was reported in 26 patients and a benign diagnosis in 18. In the remaining 12 patients a definite diagnosis was not reached, and further testing was required.In an "intention-to-treat analysis" (69 patients in total), the diagnostic accuracy of MT was 63%, the sensitivity for malignancy was 59% [95% confidence interval (CI)=43%-73%], the specificity was 100% (95% CI=86%-100%), and the negative likelihood ratio was 0.41 (95% CI=0.29-0.58). Considering the 56 patients in whom it was possible to complete the procedure, the diagnostic accuracy was 78%, the sensitivity for malignancy was 74% (95% CI=54%-87%), the specificity was 100% (95% CI=83.75%-100%), and the negative likelihood ratio was 0.27 (95% CI=0.15%-0.45%). No mortality was reported.

CONCLUSIONS: MT performed under local anesthesia with a semirigid scope is a simple and safe procedure with an acceptable sensitivity for malignancy.

Original languageEnglish
JournalJournal of Bronchology & Interventional Pulmonology
Volume21
Issue number3
Pages (from-to)215-9
Number of pages5
ISSN1944-6586
DOIs
Publication statusPublished - Jul 2014

Fingerprint

Dive into the research topics of 'Diagnostic accuracy and safety of semirigid thoracoscopy in exudative pleural effusions in Denmark'. Together they form a unique fingerprint.

Cite this