Skip to main navigation Skip to search Skip to main content

Design and validation of a therapeutic EUS training program using a live animal model: Taking training to the next level

  • Leonardo Sosa-Valencia*
  • , Jerôme Huppertz
  • , Fanélie Wanert
  • , Francois Haberzetser
  • , Lee Swanström
  • , Benedetto Mangiavillano
  • , Pierre Eisendrath
  • , Pierre Deprez
  • , Carlos Robles-Medranda
  • , Silvia Carrara
  • , Mohammad A. Al-Haddad
  • , Peter Vilmann
  • , Stephane Koch
  • , Alberto Larghi
  • , Mouen Khashab
  • *Corresponding author for this work
9 Citations (Scopus)

Abstract

Background and Objectives: EUS has evolved into a therapeutic modality for gastrointestinal disorders. Simulators, ex vivo models, and phantoms are the current teaching methods for therapeutic EUS (TEUS). We create and evaluate a high-fidelity simulated live animal model (HiFi SAM) for teaching endoscopists TEUS. Materials and Methods: Designing a curriculum that uses HiFi SAM and enables trainees to perform realistic procedures with expert mentors. Results: Twenty-seven trainees participated in a 3-day program with 6 h of theoretical and 14 h of hands using life HiFi SAM. Eighteen experts participated. Twenty-two (20-25) TEUS were defined for each HiFi SAM, and 616 were performed in all. Of 616/264 (43%) were evaluated with a mean of 88 per course (ranging between 80 and 95). Ninety-one percent (240/264) of the procedures were completed successfully. In 24, success was not achieved due to technical and/or model problems. Student rating of HiFi SAM was: 71% excellent rating (scale 8-10) and 95% excellent/good. The HiFi SAM procedure evaluation was (scale 1-5): fine-needle biopsy: 4.79, radiofrequency: 4.76, common bile duct and gallbladder drainage: 4.75, cystic drainages: 4.72, neurolysis: 4.55, microbiopsy: 4.50, and hepatogastric drainage: 4.04, with an overall satisfaction rate of 4.56 (91%). A short survey showed: 83% would recommend absolutely (17% most likely), 33% think that ITEC training was sufficient for their practice, and 66% would like additional training, especially more practice in specific techniques rather than more clinical case discussion. Regarding impact on their practice, 66% of the trainees started a new procedure and/or noted improvement in previous ones. Conclusion: HiFi SAM is a complex model; however, experts and trainees are satisfied with the training this new curriculum provided.

Original languageEnglish
JournalEndoscopic Ultrasound
Volume11
Issue number2
Pages (from-to)112-121
Number of pages10
ISSN2303-9027
DOIs
Publication statusPublished - 1 Mar 2022

Keywords

  • education
  • EUS
  • fine-needle biopsy
  • FNA
  • radiofrequency
  • teaching
  • training

Fingerprint

Dive into the research topics of 'Design and validation of a therapeutic EUS training program using a live animal model: Taking training to the next level'. Together they form a unique fingerprint.

Cite this