TY - JOUR
T1 - Comparison of temporal artery ultrasound versus biopsy in the diagnosis of giant cell arteritis
AU - Hansen, Michael Stormly
AU - Terslev, Lene
AU - Jensen, Mads Radmer
AU - Brittain, Jane Maestri
AU - Døhn, Uffe Møller
AU - Faber, Carsten
AU - Heegaard, Steffen
AU - Klefter, Oliver Niels
AU - Kønig, Elisabeth Bay
AU - Subhi, Yousif
AU - Wiencke, Anne Katrine
AU - Hamann, Steffen
N1 - © 2022. The Author(s), under exclusive licence to The Royal College of Ophthalmologists.
PY - 2023/2
Y1 - 2023/2
N2 - BACKGROUND/OBJECTIVES: Giant cell arteritis (GCA) is a medical and ophthalmological emergency due to risk of stroke and sudden irreversible loss of vision. Fast and accurate diagnosis is important to prevent complications and long-term high dose glucocorticoids toxicity. Temporal artery biopsy is gold standard for diagnosing GCA. However, temporal artery ultrasound is a fast and non-invasive procedure which may provide a supplement or an alternative to biopsy. This study assesses the diagnostic performance of ultrasound and biopsy in the diagnosis of GCA.SUBJECTS/METHODS: Examination results of patients suspected of having GCA in the period from August 2018 to June 2019 were reviewed. Patients underwent clinical examination and blood tests. Within a few days of starting glucocorticoid treatment, temporal ultrasound and unilateral biopsy were performed. Experienced physicians established the final clinical diagnosis at 6-months follow-up.RESULTS: Seventy-eight patients underwent both ultrasound and biopsy. Thirty-five (45%) received the final clinical diagnosis of GCA. Compared with the final clinical diagnosis, biopsy had a sensitivity of 69% (51-83%) and a specificity of 100% (92-100%), and ultrasound a sensitivity of 63% (45-79%) and a specificity of 79% (64-94%). Area under the receiver operating characteristics curves were 0.84 and 0.71 for biopsy and ultrasound respectively (p = 0.048). False negative rate of ultrasound was 4 out of 78 (5%).CONCLUSION: Sensitivity of ultrasound is almost on par with that of biopsy although the overall diagnostic accuracy of ultrasound was slightly lower. We find that ultrasound is a reliable tool for first line diagnosis of GCA.
AB - BACKGROUND/OBJECTIVES: Giant cell arteritis (GCA) is a medical and ophthalmological emergency due to risk of stroke and sudden irreversible loss of vision. Fast and accurate diagnosis is important to prevent complications and long-term high dose glucocorticoids toxicity. Temporal artery biopsy is gold standard for diagnosing GCA. However, temporal artery ultrasound is a fast and non-invasive procedure which may provide a supplement or an alternative to biopsy. This study assesses the diagnostic performance of ultrasound and biopsy in the diagnosis of GCA.SUBJECTS/METHODS: Examination results of patients suspected of having GCA in the period from August 2018 to June 2019 were reviewed. Patients underwent clinical examination and blood tests. Within a few days of starting glucocorticoid treatment, temporal ultrasound and unilateral biopsy were performed. Experienced physicians established the final clinical diagnosis at 6-months follow-up.RESULTS: Seventy-eight patients underwent both ultrasound and biopsy. Thirty-five (45%) received the final clinical diagnosis of GCA. Compared with the final clinical diagnosis, biopsy had a sensitivity of 69% (51-83%) and a specificity of 100% (92-100%), and ultrasound a sensitivity of 63% (45-79%) and a specificity of 79% (64-94%). Area under the receiver operating characteristics curves were 0.84 and 0.71 for biopsy and ultrasound respectively (p = 0.048). False negative rate of ultrasound was 4 out of 78 (5%).CONCLUSION: Sensitivity of ultrasound is almost on par with that of biopsy although the overall diagnostic accuracy of ultrasound was slightly lower. We find that ultrasound is a reliable tool for first line diagnosis of GCA.
KW - Biopsy/methods
KW - Giant Cell Arteritis/diagnostic imaging
KW - Glucocorticoids/therapeutic use
KW - Humans
KW - Sensitivity and Specificity
KW - Temporal Arteries/diagnostic imaging
KW - Ultrasonography/methods
UR - http://www.scopus.com/inward/record.url?scp=85123838504&partnerID=8YFLogxK
U2 - 10.1038/s41433-022-01947-1
DO - 10.1038/s41433-022-01947-1
M3 - Journal article
C2 - 35094027
VL - 37
SP - 344
EP - 349
JO - Eye
JF - Eye
SN - 0950-222X
IS - 2
ER -