Comparison of INVOS 5100C and Nonin SenSmart X-100 oximeter performance in preterm infants with spontaneous apnea

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Gestational age-dependent development of the neonatal metabolome

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Changes in pulmonary oxygen content are detectable with laser absorption spectroscopy: proof of concept in newborn piglets

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Gut transit time, using radiological contrast imaging, to predict early signs of necrotizing enterocolitis

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Does height and IGF-I determine pubertal timing in girls?

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. The effect of early probiotic exposure on the preterm infant gut microbiome development

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Aerosol generation by respiratory support of neonates may be low

    Research output: Contribution to journalComment/debateResearchpeer-review

  3. The clinical usefulness of cerebral oximetry

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Changes in pulmonary oxygen content are detectable with laser absorption spectroscopy: proof of concept in newborn piglets

    Research output: Contribution to journalJournal articleResearchpeer-review

  5. Continuing decline in the prevalence of cerebral palsy in Denmark for birth years 2008–2013

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

BACKGROUND: Tissue oximeters are not interchangeable. Two instruments with sensors dedicated to preterm infants-INVOS 5100C and Nonin SenSmart X-100-have not yet been compared.

METHODS: By measuring cerebral oxygenation in ten preterm infants with spontaneous apneic episodes defined by pulse oximeter readings (SpO2) below 80%, as well as tissue oxygenation during vascular occlusion on the forearm of ten adults, simultaneously we compared performance in the hypoxic range.

RESULTS: We found the mean conversion equations to be StO2,SenSmart X-100 = 0.34 × StO2,INVOS 5100C + 44.8% during apnea in infants and StO2,SenSmart X-100 = 0.59 × StO2,INVOS 5100C + 34.4% during vascular occlusion. The individual regressions displayed large and statistically significant variations in both infants and adults. In three infants the INVOS sensor showed very little reaction to decreases in SpO2.

CONCLUSIONS: These findings confirm that different NIRS devices give very different estimates when the oxygenation is low. The large variation when compared to SpO2 suggest that the sensor placement is very important in preterm infants.