Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Comparison of four MRI protocols for detection of extrahepatic colorectal cancer metastases

Research output: Contribution to journalJournal articleResearchpeer-review

DOI

  1. Tractography reproducibility challenge with empirical data (TraCED): The 2017 ISMRM diffusion study group challenge

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Brain capillary transit time heterogeneity in healthy volunteers measured by dynamic contrast-enhanced T1 -weighted perfusion MRI

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Comparison of global cerebral blood flow measured by phase-contrast mapping MRI with (15) O-H2 O positron emission tomography

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. How to Manage (Treat) Immediate-type Adverse Reactions to GBCA

    Research output: Contribution to journalReviewResearchpeer-review

View graph of relations

PURPOSE: To compare three magnetic resonance imaging (MRI) protocols containing diffusion-weighted imaging with background suppression (DWIBS) and one traditional protocol for detecting extrahepatic colorectal cancer metastases.

MATERIALS AND METHODS: Thirty patients with extrahepatic colorectal cancer metastases were scanned in three stations from the skull base to the upper thighs using a 1.5T MRI system with six different MRI sequences; transverse and coronal T2 -weighted (T2 W) turbo spin-echo (TSE), coronal short tau inversion recovery (STIR), 3D T1 W TSE, DWIBS, and a contrast-enhanced T1 W 3D gradient echo (GRE) sequence. The six sequences were used to build four hypothetical MRI interpretive sets which were read by two readers in consensus, blinded to prior imaging. Lesions were categorized into 13 anatomic regions. Fluorodeoxyglucose / positron emission tomography / computed tomography (FDG-PET/CT) read with full access to prior imaging and clinical records was used as the reference standard. Sensitivity, specificity, and false discovery rate (FDR) were calculated as appropriate and receiver operating characteristic (ROC) curves were constructed.

RESULTS: In all, 177 malignant lesions were detected by FDG-PET/CT and distributed in 92 out of 390 scanned anatomic regions. The sensitivity was statistically higher in two out of three sets incorporating DWIBS on a per-lesion basis (66.7%, 63.3%, and 66.7% vs. 57.6%) (P = 0.01, P = 0.11, and P = 0.01, respectively) and in all sets incorporating DWIBS on a per-region basis (75.0%, 75.0%, and 77.2 vs. 66.3%) (P = 0.04, P = 0.04, and P = 0.01, respectively). There was no difference in specificity, FDR, or AUCROC . There was no difference between sets containing DWIBS irrespective of the use of a contrast-enhanced sequence.

CONCLUSION: MRI sets containing DWIBS had superior sensitivity. This sensitivity was retained when omitting a contrast-enhanced sequence.

LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1619-1630.

Original languageEnglish
JournalJournal of magnetic resonance imaging : JMRI
Volume46
Issue number6
Pages (from-to)1619-1630
Number of pages12
ISSN1053-1807
DOIs
Publication statusPublished - Dec 2017

    Research areas

  • Aged, Aged, 80 and over, Colorectal Neoplasms/pathology, Contrast Media, Diffusion Magnetic Resonance Imaging/methods, Female, Humans, Image Enhancement/methods, Magnetic Resonance Imaging/methods, Male, Middle Aged, Neoplasm Metastasis/diagnostic imaging, Prospective Studies, Reproducibility of Results, Sensitivity and Specificity, Whole Body Imaging/methods