Skip to main navigation Skip to search Skip to main content

Closed suction drainage after hip arthroplasty. Prospective study of bacterial contamination in 81 cases

S Overgaard, N O Thomsen, B Kulinski, N B Mossing

41 Citations (Scopus)

Abstract

In a prospective study we analyzed the volume of drainage, the contamination of the drain track, and drain tip in 81 primary total hip arthroplasties in 78 patients. The drain was removed when the drainage from midnight to the following morning was 20 mL or less. The drainage in the first 12 h and in total was reduced in cases with a drain period of 24 h, compared to cases with a drain period of 48 and 72 h. 4 cases had a positive culture from the wound before closure. 5 cases had a positive culture from the tip of the drain, and 6 from the drain track. The most frequently isolated microorganism was coagulase-negative Staphylococcus. The positive cultures from the drain track and tip were not correlated to the duration of drainage. 68 drains were removed within 48 h with no risk of developing wound complications.

Original languageEnglish
JournalActa Orthopaedica Scandinavica
Volume64
Issue number4
Pages (from-to)417-20
Number of pages4
ISSN0001-6470
Publication statusPublished - Aug 1993
Externally publishedYes

Fingerprint

Dive into the research topics of 'Closed suction drainage after hip arthroplasty. Prospective study of bacterial contamination in 81 cases'. Together they form a unique fingerprint.

Cite this