Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

CIED infection with either pocket or systemic infection presentation - complete device removal and long-term antibiotic treatment; long-term outcome

Research output: Contribution to journalJournal articleResearchpeer-review

  1. 30-day mortality in frail patients undergoing cardiac surgery: the results of the frailty in cardiac surgery (FICS) copenhagen study

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Relationship Between Invasive Hemodynamics and Liver Function in Advanced Heart Failure

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Atrial fibrillation and anticoagulation in patients with breast cancer

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. A national needs assessment study to determine procedures for simulation-based training in cardiology in Denmark

    Research output: Contribution to journalJournal articleResearchpeer-review

  5. Contemporary practice of CRT implantation in scandinavia compared to Europe

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Accelerated treatment of endocarditis-The POET II trial: Rationale and design of a randomized controlled trial

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Long-Term Adverse Cardiac Outcomes in Patients With Sarcoidosis

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Valve regurgitation in patients surviving endocarditis and the subsequent risk of heart failure

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

OBJECTIVE: Cardiovascular implantable electronic device (CIED) infections are increasing in numbers. The objective was to review the clinical presentation and outcome in patients affected with CIED infections with either local pocket or systemic presentation.

DESIGN: All device removals due to CIED infection during the period from 2005 to 2012 were retrospectively reviewed. CIED infections were categorized as systemic or pocket infections. Treatment included complete removal of the device, followed by antibiotic treatment of six weeks.

RESULTS: Seventy-one device removals due to infection (32 systemic and 39 pocket infections) were recorded during the study period. Median follow-up time was 26 (IQR 9-41) months, 30 day and 12 month mortality were 4% and 14%, respectively. There was no long-term difference in mortality between patients with pocket vs. systemic infection (p = 0.48). During follow-up no relapses and two cases of new infections were noted (2.8%).

CONCLUSIONS: CIED infection with systemic or pocket infection was difficult to distinguish in clinical presentation and outcome. Complete device removal and antibiotic treatment of long duration was safe and without relapses.

Original languageEnglish
JournalScandinavian cardiovascular journal : SCJ
Volume50
Issue number1
Pages (from-to)52-7
Number of pages6
ISSN1401-7431
DOIs
Publication statusPublished - Feb 2016

ID: 45992788