Behavioural digital biomarkers enable real-time monitoring of patient-reported outcomes: a substudy of the multicentre, prospective observational SafeHeart study

Mzh Kolk, D M Frodi, J Langford, C J Meskers, T O Andersen, P K Jacobsen, N Risum, H L Tan, J H Svendsen, R E Knops, S Z Diederichsen, Fvy Tjong*

*Corresponding author for this work
2 Citations (Scopus)

Abstract

AIMS: Patient-reported outcome measures (PROMs) serve multiple purposes, including shared decision-making and patient communication, treatment monitoring, and health technology assessment. Patient monitoring using PROMs is constrained by recall and non-response bias, respondent burden, and missing data. We evaluated the potential of behavioural digital biomarkers obtained from a wearable accelerometer to achieve personalized predictions of PROMs.

METHODS AND RESULTS: Data from the multicentre, prospective SafeHeart study conducted at Amsterdam University Medical Center in the Netherlands and Copenhagen University Hospital, Rigshospitalet in Copenhagen, Denmark, were used. The study enrolled patients with an implantable cardioverter defibrillator between May 2021 and September 2022 who then wore wearable devices with raw acceleration output to capture digital biomarkers reflecting physical behaviour. To collect PROMs, patients received the Kansas City Cardiomyopathy Questionnaire (KCCQ) and EuroQoL 5-Dimensions 5-Level (EQ5D-5L) questionnaire at two instances: baseline and after six months. Multivariable Tobit regression models were used to explore associations between digital biomarkers and PROMs, specifically whether digital biomarkers could enable PROM prediction. The study population consisted of 303 patients (mean age 62.9 ± 10.9 years, 81.2% male). Digital biomarkers showed significant correlations to patient-reported physical and social limitations, severity and frequency of symptoms, and quality of life. Prospective validation of the Tobit models indicated moderate correlations between the observed and predicted scores for KCCQ [concordance correlation coefficient (CCC) = 0.49, mean difference: 1.07 points] and EQ5D-5L (CCC = 0.38, mean difference: 0.02 points).

CONCLUSION: Wearable digital biomarkers correlate with PROMs, and may be leveraged for real-time prediction. These findings hold promise for monitoring of PROMs through wearable accelerometers.

Original languageEnglish
JournalEuropean heart journal. Quality of care & clinical outcomes
Volume10
Issue number6
Pages (from-to)531-542
Number of pages12
ISSN2058-5225
DOIs
Publication statusPublished - 13 Sept 2024

Keywords

  • Aged
  • Biomarkers/blood
  • Defibrillators, Implantable
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Netherlands
  • Patient Reported Outcome Measures
  • Prospective Studies
  • Quality of Life
  • Surveys and Questionnaires
  • Wearable Electronic Devices
  • Patient-reported outcome measure
  • Quality of life
  • Digital health
  • Wearable technology

Fingerprint