Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Automated EEG source imaging: A retrospective, blinded clinical validation study

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Diagnostic yield of high-density versus low-density EEG: The effect of spatial sampling, timing and duration of recording

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Oscillatory connectivity as a diagnostic marker of dementia due to Alzheimer's disease

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Need to find a signature of abnormal brain oscillations in task-specific focal dystonia

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Diagnostic yield of standard-wake and sleep EEG recordings

    Research output: Contribution to journalJournal articleResearchpeer-review

  5. Reply to "is it significant? Is it relevant?"

    Research output: Contribution to journalComment/debateResearchpeer-review

  1. Diagnostic yield of high-density versus low-density EEG: The effect of spatial sampling, timing and duration of recording

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Transcriptome analysis in patients with temporal lobe epilepsy

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Infections seem to be more frequent before onset of pediatric multiple sclerosis: A Danish nationwide nested case-control study

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Electromagnetic source imaging in presurgical workup of patients with epilepsy: A prospective study

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

OBJECTIVE: To evaluate the accuracy of automated EEG source imaging (ESI) in localizing epileptogenic zone.

METHODS: Long-term EEG, recorded with the standard 25-electrode array of the IFCN, from 41 consecutive patients with focal epilepsy who underwent resective surgery, were analyzed blinded to the surgical outcome. The automated analysis comprised spike-detection, clustering and source imaging at the half-rising time and at the peak of each spike-cluster, using individual head-models with six tissue-layers and a distributed source model (sLORETA). The fully automated approach presented ESI of the cluster with the highest number of spikes, at the half-rising time. In addition, a physician involved in the presurgical evaluation of the patients, evaluated the automated ESI results (up to four clusters per patient) in clinical context and selected the dominant cluster and the analysis time-point (semi-automated approach). The reference standard was location of the resected area and outcome one year after operation.

RESULTS: Accuracy was 61% (95% CI: 45-76%) for the fully automated approach and 78% (95% CI: 62-89%) for the semi-automated approach.

CONCLUSION: Automated ESI has an accuracy similar to previously reported neuroimaging methods.

SIGNIFICANCE: Automated ESI will contribute to increased utilization of source imaging in the presurgical evaluation of patients with epilepsy.