TY - JOUR
T1 - AuraGain™ versus i-gel™ for bronchoscopic intubation under continuous oxygenation
T2 - A randomised controlled trial
AU - Svendsen, Christine N
AU - Rosenstock, Charlotte V
AU - Glargaard, Gine L
AU - Strøm, Camilla
AU - Lange, Kai H W
AU - Lundstrøm, Lars H
N1 - © 2022 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
PY - 2022/5
Y1 - 2022/5
N2 - INTRODUCTION: After failed mask ventilation and tracheal intubation, guidelines issued by the Difficult Airway Society recommend placing a second generation supraglottic airway device to secure oxygenation. Ultimately, a secure airway can be obtained by tracheal intubation through the supraglottic airway device using a bronchoscope. In this randomised trial, we compared the AuraGain™ with the i-gel™ as conduit for bronchoscopic intubation under continuous oxygenation performed by a group of anaesthesiologists with variable experience in a general population of patients.METHOD: We randomised one hundred patients who were equally allocated to flexible bronchoscopic intubation through the i-gel™ or the AuraGain™. In a random order, 25 anaesthesiologists each performed four intubations, two using the i-gel™ and two using the AuraGain™. Our primary outcome was 'total time for airway management'; i.e. total time from manually reaching the SAD to successful FBI confirmed at the end of the first inspiratory downstroke on the capnography curve.RESULTS: In total, 87% (95% CI, 79%-92%) of the patients were successfully intubated through the allocated supraglottic airway device. There was no difference in total time for airway management between the i-gel™ and the AuraGain™ (199 vs. 227 s, p = .076). However, there was a difference in time for placement of the i-gel™, compared to the AuraGain™, (37 vs. 54 s, p < .001). There were nine failed intubations in the AuraGain™ group compared to four in the i-gel™ group (p = .147).CONCLUSION: We found no difference in total time for airway management between using the i-gel™ and using the AuraGain™.
AB - INTRODUCTION: After failed mask ventilation and tracheal intubation, guidelines issued by the Difficult Airway Society recommend placing a second generation supraglottic airway device to secure oxygenation. Ultimately, a secure airway can be obtained by tracheal intubation through the supraglottic airway device using a bronchoscope. In this randomised trial, we compared the AuraGain™ with the i-gel™ as conduit for bronchoscopic intubation under continuous oxygenation performed by a group of anaesthesiologists with variable experience in a general population of patients.METHOD: We randomised one hundred patients who were equally allocated to flexible bronchoscopic intubation through the i-gel™ or the AuraGain™. In a random order, 25 anaesthesiologists each performed four intubations, two using the i-gel™ and two using the AuraGain™. Our primary outcome was 'total time for airway management'; i.e. total time from manually reaching the SAD to successful FBI confirmed at the end of the first inspiratory downstroke on the capnography curve.RESULTS: In total, 87% (95% CI, 79%-92%) of the patients were successfully intubated through the allocated supraglottic airway device. There was no difference in total time for airway management between the i-gel™ and the AuraGain™ (199 vs. 227 s, p = .076). However, there was a difference in time for placement of the i-gel™, compared to the AuraGain™, (37 vs. 54 s, p < .001). There were nine failed intubations in the AuraGain™ group compared to four in the i-gel™ group (p = .147).CONCLUSION: We found no difference in total time for airway management between using the i-gel™ and using the AuraGain™.
UR - http://www.scopus.com/inward/record.url?scp=85124564186&partnerID=8YFLogxK
U2 - 10.1111/aas.14042
DO - 10.1111/aas.14042
M3 - Journal article
C2 - 35138634
VL - 66
SP - 589
EP - 597
JO - Acta Anaesthesiologica Scandinavica
JF - Acta Anaesthesiologica Scandinavica
SN - 0001-5172
IS - 5
ER -