Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Assessment of left ventricular outflow tract and aortic root: comparison of 2D and 3D transthoracic echocardiography with multidetector computed tomography

Research output: Contribution to journalJournal articleResearchpeer-review

DOI

  1. Prognostic value of ratio of transmitral early filling velocity to early diastolic strain rate in patients with Type 2 diabetes

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Mechanical circulatory support for decompensated heart failure: the last remaining indication for intra-aortic balloon pump?

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

AIMS: Accurate echocardiographic assessment of left ventricular outflow tract (LVOT) and the aortic root is necessary for risk stratification and choice of appropriate treatment in patients with pathologies of the aortic valve and aortic root. Conventional 2D transthoracic echocardiographic (TTE) assessment is based on the assumption of a circular shaped LVOT and aortic root, although previous studies have indicated a more ellipsoid shape. 3D TTE and multidetector computed tomography (MDCT) applies planimetry and are not dependent on geometrical assumptions. The aim was to test accuracy, feasibility, and reproducibility of 3D TTE compared to 2D TTE assessment of LVOT and aortic root areas, with MDCT as reference.

METHODS AND RESULTS: We examined 51 patients with 2D/3D TTE and MDCT at the same day. All patients were re-examined with 2D/3D TTE on a different day to evaluate 2D and 3D re-test variability. Areas of LVOT, aortic annulus, and sinus were assessed using 2D, 3D TTE, and MDCT. Both 2D/3D TTE underestimated the areas compared to MDCT; however, 3D TTE areas were significantly closer to MDCT-areas. 2D vs. 3D mean MDCT-differences: LVOT 1.61 vs. 1.15 cm2, P = 0.019; aortic annulus 1.96 vs. 1.06 cm2, P < 0.001; aortic sinus 1.66 vs. 1.08 cm2, P = 0.015. Feasibility was 3D 76-79% and 2D 88-90%. LVOT and aortic annulus areas by 3D TTE had lowest variabilities; intraobserver coefficient of variation (CV) 9%, re-test variation CV 18-20%.

CONCLUSION: Estimation of LVOT and aortic root areas using 3D TTE is feasible, more precise and more accurate than 2D TTE.

Original languageEnglish
JournalEuropean heart journal cardiovascular Imaging
Volume20
Issue number10
Pages (from-to)1156-1163
Number of pages8
ISSN1525-2167
DOIs
Publication statusPublished - 1 Oct 2019

ID: 58015733