Accuracy and sensitivity of three-dimensional echocardiography to detect changes in right ventricular volumes: comparison study with cardiac magnetic resonance

K A Myhr*, C B Kristensen, F H G Pedersen, C Hassager, N Vejlstrup, R Mattu, R Pecini, R Mogelvang

*Corresponding author for this work

Abstract

We aimed to investigate the ability of three-dimensional transthoracic echocardiography (3DE) to detect changes in RV volumes compared to cardiac magnetic resonance (CMR). Eighty-five subjects including 45 with no known cardiac disease and 40 patients with a variety of cardiac diseases were included. Two- and three-dimensional echocardiography as well as CMR of the RV was performed before and after infusion of on average two litres of saline. Examinations were analysed with estimation of RV dimensions, volumes and ejection fraction (RVEF). Intra- and inter-examiner variability was evaluated in 25 patients randomly selected from the cohort. Three-dimensional echocardiography underestimated volumes and RVEF compared to CMR with mean differences and 95% limits of agreement of 110.3 ± 59 mL for RV end-diastolic volume (RVEDV), 43.3 ± 32 mL for RV end-systolic volume (RVESV) and 3.5 ± 10.7% for RVEF. CMR was more reproducible than 3DE, with intra-observer coefficient of variation (CV) of 4% vs. 14.2% for RVEDV, 9.7% vs. 16.7% for RVESV and 6.3% vs. 8.6% for RVEF. The RVEDV, RVESV and RV stroke volume (RVSV) by CMR significantly increased after saline infusion by 15.3 ± 16.2 mL, 3.5 ± 14.2 mL and 11.8 ± 12.6 mL, respectively, as well as RVEF by 1.5 ± 4.6% (p < 0.05). However, 3DE was not able to detect any of these changes in RV volumes (p ≥ 0.05). Compared to CMR imaging of the RV, three-dimensional echocardiography appears unable and unreliable in detecting RV volume changes of less than 15%, highlighting the need for cautious utility of 3DE in these circumstances.

Original languageEnglish
JournalThe international journal of cardiovascular imaging
Volume37
Issue number2
Pages (from-to)493-502
Number of pages10
ISSN1569-5794
DOIs
Publication statusPublished - Feb 2021

Keywords

  • Adult
  • Case-Control Studies
  • Echocardiography, Three-Dimensional
  • Female
  • Heart Diseases/diagnostic imaging
  • Humans
  • Magnetic Resonance Imaging, Cine
  • Male
  • Middle Aged
  • Observer Variation
  • Predictive Value of Tests
  • Reproducibility of Results
  • Stroke Volume
  • Ventricular Function, Right

Fingerprint

Dive into the research topics of 'Accuracy and sensitivity of three-dimensional echocardiography to detect changes in right ventricular volumes: comparison study with cardiac magnetic resonance'. Together they form a unique fingerprint.

Cite this