A randomised cross-over comparison of the transverse and longitudinal techniques for ultrasound-guided identification of the cricothyroid membrane in morbidly obese subjects

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

APA

CBE

MLA

Vancouver

Author

Bibtex

@article{8e87a1fbc87f4d19bb011e1c5a3b8f88,
title = "A randomised cross-over comparison of the transverse and longitudinal techniques for ultrasound-guided identification of the cricothyroid membrane in morbidly obese subjects",
abstract = "We compared the transverse and longitudinal approaches to ultrasound-guided identification of the cricothyroid membrane, to determine which was faster and more successful. Forty-two anaesthetists received a one-hour structured training programme consisting of e-learning, a lecture and hands-on training, and then applied both techniques in a randomised, cross-over sequence to obese females with body mass index 39.0 - 43.9 kg.m(-2) . The mean (SD) time to identify the cricothyroid membrane was 24.0 (12.4) s using the transverse technique compared with 37.6 (17.9) s for the longitudinal technique (p = 0.0003). Successful identification of the cricothyroid membrane was achieved by 38 (90{\%}) anaesthetists using either technique. All anaesthetists were successful in identifying the cricothyroid membrane with at least one of the techniques. We advocate the learning and application of these two techniques for identification of the cricothyroid membrane before starting anaesthesia in difficult patients, especially when anatomical landmarks are impalpable. Further use in emergency situations is feasible, if clinicians have experience and the ultrasound machine is readily available.",
author = "Kristensen, {M S} and Teoh, {W H} and Rudolph, {S S} and R Hesselfeldt and J B{\o}rglum and Tvede, {Michael Friis}",
note = "{\circledC} 2016 The Association of Anaesthetists of Great Britain and Ireland.",
year = "2016",
month = "4",
day = "2",
doi = "10.1111/anae.13465",
language = "English",
volume = "71",
pages = "675--83",
journal = "Anaesthesia",
issn = "0003-2409",
publisher = "Wiley-Blackwell Publishing Ltd",
number = "6",

}

RIS

TY - JOUR

T1 - A randomised cross-over comparison of the transverse and longitudinal techniques for ultrasound-guided identification of the cricothyroid membrane in morbidly obese subjects

AU - Kristensen, M S

AU - Teoh, W H

AU - Rudolph, S S

AU - Hesselfeldt, R

AU - Børglum, J

AU - Tvede, Michael Friis

N1 - © 2016 The Association of Anaesthetists of Great Britain and Ireland.

PY - 2016/4/2

Y1 - 2016/4/2

N2 - We compared the transverse and longitudinal approaches to ultrasound-guided identification of the cricothyroid membrane, to determine which was faster and more successful. Forty-two anaesthetists received a one-hour structured training programme consisting of e-learning, a lecture and hands-on training, and then applied both techniques in a randomised, cross-over sequence to obese females with body mass index 39.0 - 43.9 kg.m(-2) . The mean (SD) time to identify the cricothyroid membrane was 24.0 (12.4) s using the transverse technique compared with 37.6 (17.9) s for the longitudinal technique (p = 0.0003). Successful identification of the cricothyroid membrane was achieved by 38 (90%) anaesthetists using either technique. All anaesthetists were successful in identifying the cricothyroid membrane with at least one of the techniques. We advocate the learning and application of these two techniques for identification of the cricothyroid membrane before starting anaesthesia in difficult patients, especially when anatomical landmarks are impalpable. Further use in emergency situations is feasible, if clinicians have experience and the ultrasound machine is readily available.

AB - We compared the transverse and longitudinal approaches to ultrasound-guided identification of the cricothyroid membrane, to determine which was faster and more successful. Forty-two anaesthetists received a one-hour structured training programme consisting of e-learning, a lecture and hands-on training, and then applied both techniques in a randomised, cross-over sequence to obese females with body mass index 39.0 - 43.9 kg.m(-2) . The mean (SD) time to identify the cricothyroid membrane was 24.0 (12.4) s using the transverse technique compared with 37.6 (17.9) s for the longitudinal technique (p = 0.0003). Successful identification of the cricothyroid membrane was achieved by 38 (90%) anaesthetists using either technique. All anaesthetists were successful in identifying the cricothyroid membrane with at least one of the techniques. We advocate the learning and application of these two techniques for identification of the cricothyroid membrane before starting anaesthesia in difficult patients, especially when anatomical landmarks are impalpable. Further use in emergency situations is feasible, if clinicians have experience and the ultrasound machine is readily available.

U2 - 10.1111/anae.13465

DO - 10.1111/anae.13465

M3 - Journal article

VL - 71

SP - 675

EP - 683

JO - Anaesthesia

JF - Anaesthesia

SN - 0003-2409

IS - 6

ER -

ID: 46376568