A method to determine methylmethacrylate in air.

E Darre, J Gottlieb, P M Nielsen, J S Jensen

16 Citations (Scopus)

Abstract

To determine the air concentrations of methylmethacrylate monomer and thus obtain information about the safety in the operating theater, a methylmethacrylate Dräger tube was used in connection with a bellows pump. This method gives an instantly readable value correlated with more complicated gas chromatographic measurements.
Translated title of the contributionA method to determine methylmethacrylate in air.
Original languageEnglish
JournalActa Orthopaedica
Volume59
Issue number3
Pages (from-to)270-271
Number of pages2
ISSN1745-3674
Publication statusPublished - 1988

Cite this