Abstract
To determine the air concentrations of methylmethacrylate monomer and thus obtain information about the safety in the operating theater, a methylmethacrylate Dräger tube was used in connection with a bellows pump. This method gives an instantly readable value correlated with more complicated gas chromatographic measurements.
| Translated title of the contribution | A method to determine methylmethacrylate in air. |
|---|---|
| Original language | English |
| Journal | Acta Orthopaedica |
| Volume | 59 |
| Issue number | 3 |
| Pages (from-to) | 270-271 |
| Number of pages | 2 |
| ISSN | 1745-3674 |
| Publication status | Published - 1988 |