A closer look at RapidArc® radiosurgery plans using very small fields

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Comparison of 11 automated PET segmentation methods in lymphoma

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Simulating effects of brain atrophy in longitudinal PET imaging with an anthropomorphic brain phantom

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Repeated diffusion MRI reveals earliest time point for stratification of radiotherapy response in brain metastases

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Optimized MLAA for quantitative non-TOF PET/MR of the brain

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. 3D image-guided treatment planning for Ruthenium-106 brachytherapy of choroidal melanomas

    Research output: Contribution to journalReviewpeer-review

  2. Dose-Response and Normal Tissue Complication Probabilities after Proton Therapy for Choroidal Melanoma

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations
RapidArc® has become the treatment of choice for an increasing number of treatment sites in many clinics. The extensive use of multiple subfields in RapidArc® treatments presents unique challenges, especially for small targets treated in few fractions. In this work, very small static fields and subsequently RapidArc® and conventional plans for two targets (0.4 and 9.9 cm(3)) were investigated. Doses from static fields 1-4 MLC leaves (0.25-1.00 cm) wide, and larger fields with 1-4 MLC leaves closed in their centres, were measured using the portal dosimeter-based QA system EPIQA (v 1.3) and gafchromic film. RapidArc and conventional plans for two tumours were then measured using EPIQA, gafchromic EBT2 film and the phantom-based QA system Delta4. Eclipse 8.6 and 8.9, grid spacings of 1.25 and 2.50 mm and a Varian HD linac were used. For static fields one MLC leaf wide, the dose was underestimated by Eclipse by as much as 53% (v 8.6, 2.5 mm grid). Eclipse underestimated the dose downstream from a few MLC leaves closed in the centre of a large MLC field by as much as 30%. Eclipse consistently overestimated the width of the penumbra by about 100%. For the conventional plans, there was good agreement between the calculated and measured dose for the 9.9 cm(3) PTV, but a 10% underdose was observed for the 0.4 cm(3) PTV. For the RapidArc® plans, the measured dose for the 9.9 cm(3) PTV was in good agreement with the calculated one. However, for the 0.4 cm(3) PTV about 10% overdosing was detected (Eclipse v 8.6, 2.5 mm grid spacing). EPIQA data indicated that the measured dose profiles were overmodulated compared to the calculated one. The use of small subfields, typically a few MLC leaves wide, or larger fields with one or a few MLC leaves closed in its centre can result in significant errors in the dose calculation. The detector systems used vary in their ability to detect the discrepancies. Using a smaller grid size and newer version of Eclipse reduces the discrepancies observed in this work but does not eliminate them.
Original languageEnglish
JournalPhysics in Medicine and Biology
Volume56
Issue number6
Pages (from-to)1853-63
Number of pages11
ISSN0031-9155
DOIs
Publication statusPublished - 21 Mar 2011

ID: 32306366