Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Ventilation in day care centers and sick leave among nursery children

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Emergence of Aspergillus fumigatus azole-resistance in azole-naïve COPD patients and their homes

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Variation in residential radon levels in new Danish homes

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Long-term exposure to indoor air pollution and wheezing symptoms in infants

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Male factor infertility and risk of death: a nationwide record-linkage study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Long-term wind turbine noise exposure and the risk of incident atrial fibrillation in the Danish Nurse cohort

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Association Between Long-Term Exposure to Wind Turbine Noise and the Risk of Stroke: Data From the Danish Nurse Cohort

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Road traffic noise and markers of adiposity in the Danish nurse cohort: A cross sectional study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

Several studies have reported poor indoor air quality (IAQ) in day care centers (DCCs), and other studies have shown that children attending them have an increased risk of respiratory and gastrointestinal infections. The aim of this study was to investigate whether there is an association between ventilation in DCCs and sick leave among nursery children. Data on child sick leave within an 11-week period were obtained for 635 children attending 20 DCCs. Ventilation measurements included three proxies of ventilation: air exchange rate (ACR) measured with the decay method, ACR measured by the perfluorocarbon tracer gas (PFT) method, and CO2 concentration measured over a 1-week period. All but two DCCs had balanced mechanical ventilation system, which could explain the low CO2 levels measured. The mean concentration of CO2 was 643 ppm, exceeding 1000 ppm in only one DCC. A statistically significant inverse relationship between the number of sick days and ACR measured with the decay method was found for crude and adjusted analysis, with a 12% decrease in number of sick days per hour increase in ACR measured with the decay method. This study suggests a relationship between sick leave among nursery children and ventilation in DCCs, as measured with the decay method.

OriginalsprogEngelsk
TidsskriftIndoor Air
Vol/bind26
Udgave nummer2
Sider (fra-til)157-67
Antal sider11
ISSN0905-6947
DOI
StatusUdgivet - apr. 2016

ID: 50145833