Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Validity and reliability of an ultrasound measurement of the free length of the Achilles tendon

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Sepsis-related Organ Failure Assessment Score is a strong predictor of survival in acute-on-chronic liver failure

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Prevention of parastomal hernia using mesh in patients undergoing rectum extirpation

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Temporal trends in length of stay and readmissions after fast-track hip and knee arthroplasty

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Successful performance of pediatric renography does not require sedation

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. Hydrochloric acid prolongs the lifetime of central venous catheters in haematologic patients with bacteraemia

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. The problem is not necessarily the data, it is the interpretation

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. An exploration of the methods to determine the protein-specific synthesis and breakdown rates in vivo in humans

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. High-Volume Injection with and without Corticosteroid in Chronic Midportion Achilles Tendinopathy

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

INTRODUCTION: Valid length measurements of the different segments of the Achilles tendon are needed in order to investigate if differential elongation of the Achilles tendon takes place after rupture. The purpose of this paper was to present data concerning the accuracy and reliability of an ultrasound measurement of the free part of the Achilles tendon.

METHODS: Both legs of 19 non-injured subjects were examined by magnetic resonance imagining (MRI) and ultrasound. The length from the distal tip of the soleus muscle to the tendon insertion on the calcaneus was measured by three independent ultrasound examiners. Repeated ultrasound measurements were performed and compared with MRI measurements. Intra-rater and inter-rater reliability and the agreement between MRI and ultrasound were determined. Data were evaluated using the intraclass correlation coefficient (ICC), the standard error of the measurement (SEM) and the minimal detectable change (MDC).

RESULTS: The measurement showed excellent intra-rater reliability (ICC = 0.94 (95% confidence interval (CI): 0.91-0.96), SEM = 5 mm and MDC = 13 mm) and inter-rater reliability (ICC = 0.96 (95% CI: 0.93-0.97), SEM = 4 mm and MDC = 11 mm). On average, ultrasound measurements exceeded the MRI measurements by 2 mm (non-significant), resulting in a measurement error of 5%.

CONCLUSIONS: The ultrasound measurement of the free part of the Achilles tendon showed good reliability and accuracy. For comparison between groups of non-injured subjects, differences of > 5 mm can be detected. For repeated assessment of individual subject differences ≥ 13 mm can be detected.

FUNDING: none.

TRIAL REGISTRATION: Institutional Review Board of Zealand, Denmark, Ref. no: SJ-318.

OriginalsprogEngelsk
Artikelnummerpii: A5453
TidsskriftDanish Medical Journal
Vol/bind65
Udgave nummer3
ISSN1603-9629
StatusUdgivet - mar. 2018

ID: 55649943