TY - JOUR
T1 - Validation of a New Method for 2D Fusion Imaging Registration in a System Prepared Only for 3D
AU - Edsfeldt, Andreas
AU - Sonesson, Björn
AU - Rosén, Helena
AU - Petri, Marcelo H
AU - Hongku, Kiattisak
AU - Resch, Timothy
AU - Dias, Nuno V
PY - 2020/6
Y1 - 2020/6
N2 - Purpose: To validate a new 2D-3D registration method of fusion imaging during aortic repair in a system prepared only for 3D-3D registration and to compare radiation doses and accuracy. Materials and Methods: The study involved 189 patients, including 94 patients (median age 70 years; 85 men) who underwent abdominal endovascular aneurysm repair (EVAR) with 2D-3D fusion on an Artis zee imaging system and 95 EVAR patients (median age 70 years; 81 men) from a prior study who had 3D-3D registration done using cone beam computed tomography (CBCT). For the 2D-3D registration, an offline CBCT of the empty operating table was imported into the intraoperative dataset and superimposed on the preoperative computed tomography angiogram (CTA). Then 2 intraoperative single-frame 2D images of the skeleton were aligned with the patient's skeleton on the preoperative CTA to complete the registration process. A digital subtraction angiogram was done to correct any misalignment of the aortic CTA volume. Values are given as the median [interquartile range (IQR) Q1, Q3]. Results: The 2D-3D registration had an accuracy of 4.0 mm (IQR 3.0, 5.0) after bone matching compared with the final correction with DSA (78% within 5 mm). By applying the 2D-3D protocol the radiation exposure (dose area product) from the registration of the fusion image was significantly reduced compared with the 3D-3D registration [1.12 Gy∙cm2 (IQR 0.41, 2.14) vs 43.4 Gy∙cm2 (IQR 37.1, 49.0), respectively; p<0.001). Conclusion: The new 2D-3D registration protocol based on 2 single-frame images avoids an intraoperative CBCT and can be used for fusion imaging registration in a system originally designed for 3D-3D only. This 2D-3D registration protocol is accurate and leads to a significant reduction in radiation exposure.
AB - Purpose: To validate a new 2D-3D registration method of fusion imaging during aortic repair in a system prepared only for 3D-3D registration and to compare radiation doses and accuracy. Materials and Methods: The study involved 189 patients, including 94 patients (median age 70 years; 85 men) who underwent abdominal endovascular aneurysm repair (EVAR) with 2D-3D fusion on an Artis zee imaging system and 95 EVAR patients (median age 70 years; 81 men) from a prior study who had 3D-3D registration done using cone beam computed tomography (CBCT). For the 2D-3D registration, an offline CBCT of the empty operating table was imported into the intraoperative dataset and superimposed on the preoperative computed tomography angiogram (CTA). Then 2 intraoperative single-frame 2D images of the skeleton were aligned with the patient's skeleton on the preoperative CTA to complete the registration process. A digital subtraction angiogram was done to correct any misalignment of the aortic CTA volume. Values are given as the median [interquartile range (IQR) Q1, Q3]. Results: The 2D-3D registration had an accuracy of 4.0 mm (IQR 3.0, 5.0) after bone matching compared with the final correction with DSA (78% within 5 mm). By applying the 2D-3D protocol the radiation exposure (dose area product) from the registration of the fusion image was significantly reduced compared with the 3D-3D registration [1.12 Gy∙cm2 (IQR 0.41, 2.14) vs 43.4 Gy∙cm2 (IQR 37.1, 49.0), respectively; p<0.001). Conclusion: The new 2D-3D registration protocol based on 2 single-frame images avoids an intraoperative CBCT and can be used for fusion imaging registration in a system originally designed for 3D-3D only. This 2D-3D registration protocol is accurate and leads to a significant reduction in radiation exposure.
KW - Aged
KW - Anatomic Landmarks
KW - Aorta, Abdominal/diagnostic imaging
KW - Aortic Aneurysm, Abdominal/diagnostic imaging
KW - Aortography/adverse effects
KW - Blood Vessel Prosthesis Implantation
KW - Computed Tomography Angiography/adverse effects
KW - Endovascular Procedures
KW - Female
KW - Humans
KW - Imaging, Three-Dimensional/adverse effects
KW - Male
KW - Predictive Value of Tests
KW - Radiation Dosage
KW - Radiation Exposure/adverse effects
KW - Reproducibility of Results
KW - Risk Factors
U2 - 10.1177/1526602820912223
DO - 10.1177/1526602820912223
M3 - Journal article
C2 - 32193989
SN - 1526-6028
VL - 27
SP - 468
EP - 472
JO - Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
JF - Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
IS - 3
ER -