Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

UTE T2* mapping of tendinopathic patellar tendons: an MRI reproducibility study

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Tattoo complications and magnetic resonance imaging: a comprehensive review of the literature

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. New Section Editor: Cardiac and Cardiovascular Imaging

    Publikation: Bidrag til tidsskriftTidsskriftartikelFormidling

  3. The accuracy of titanium contrast-enhanced mammography: a retrospective multicentric study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Adherence to guidelines aimed at preventing post-contrast acute kidney injury (PC-AKI) in radiology practices: a survey study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. New section editor: Breast Imaging

    Publikation: Bidrag til tidsskriftTidsskriftartikelFormidling

  1. The influence of an orthopaedic walker boot on forefoot force

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Positional changes in lumbar disc herniation during standing or lumbar extension: a cross-sectional weight-bearing MRI study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Muscles adaptation to aging and training: architectural changes - a randomised trial

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Age-related myofiber atrophy in old mice is reversed by ten weeks voluntary high-resistance wheel running

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

Background: There is currently a lack of imaging modalities that can be used as a sensitive measure in tendinopathy. Recent findings suggest the applicability of ultra-short echo time (UTE) magnetic resonance imaging (MRI) T2* mapping in tendons, but the reproducibility remains unknown. Purpose: To evaluate test–retest reproducibility of UTE MRI T2* mapping of tendinopathic patellar tendons and to evaluate the intra- and inter-observer reproducibility of the measurement. Material and Methods: Fifteen patients with chronic patellar tendinopathy were evaluated with UTE MRI twice in a 3.0-T scanner on the same day. Manual segmentation of the patellar tendon was performed by two blinded investigators and automated T2*map reconstruction was performed in custom-made software. Results: There was a significant and numerically small difference in test–retest T2* values (T2*mean diff = 0.06 ± 0.07 ms ≈ 3.7%; P = 0.006) with an ICC = 0.91 (95% confidence interval [CI] 0.58–0.98; typical error of 3.0%). The intra- and inter-observer reproducibility showed no significant bias (P = 0.493 and P = 0.052), and generally substantial reproducibility was demonstrated for T2* (intra-observer ICC = 0.99; 95% CI 0.98–1.00 and inter-observer ICC = 0.99; 95% CI 0.96–1.00, and typical error 1.3% and 1.3%, respectively). Conclusion: These data demonstrate a small bias between repeated measurements for UTE T2*, but with a very low associated mean difference (3.7%) between the two tests. The high ICC values and low typical error % demonstrate reproducibility of repeated T2*-mapping sessions. Further, the method showed substantial intra- and inter-observer reproducibility for T2* values proving feasibility for use of UTE T2* mapping in research and clinical practice.

OriginalsprogEngelsk
TidsskriftActa Radiologica
Vol/bind62
Udgave nummer2
Sider (fra-til)215-224
Antal sider10
ISSN0284-1851
DOI
StatusUdgivet - feb. 2021

ID: 61626606