TY - JOUR
T1 - Transorbital sonography
T2 - A non-invasive bedside screening tool for detection of pseudotumor cerebri syndrome
AU - Korsbæk, Johanne Juhl
AU - Hagen, Snorre Malm
AU - Schytz, Henrik W
AU - Vukovic-Cvetkovic, Vlasta
AU - Wibroe, Elisabeth Arnberg
AU - Hamann, Steffen
AU - Jensen, Rigmor H
PY - 2022/10
Y1 - 2022/10
N2 - BACKGROUND: Our objective was to assess optic nerve sheath diameter (a marker of elevated intracranial pressure) and optic disc elevation (a marker of papilledema) in pseudotumor cerebri syndrome using transorbital sonography.METHODS: The study was a prospective case-control study. We included patients with new-onset pseudotumor cerebri syndrome and matched healthy controls. All had fundoscopy, lumbar puncture with opening pressure and transorbital sonography. Sonography was assessed by a blinded observer.RESULTS: We evaluated 45 patients and included 23 cases. We recruited 35 controls. Optic nerve sheath diameter was larger in pseudotumor cerebri syndrome compared to controls (6.3 ± 0.9 mm versus 5.0 ± 0.5 mm, p < 0.001) and so was optic disc elevation (0.9 ± 0.4 mm versus 0.4 ± 0.1 mm, p < 0.001). The optimal cut-off point for optic nerve sheath diameter was 6 mm with a sensitivity of 74% for prediction of pseudotumor cerebri syndrome and 68% for prediction of elevated opening pressure. Specificity was 94%. The optimal cut-off point for optic disc elevation was 0.6 mm. Sensitivity was 100% and specificity 83% for prediction of pseudotumor cerebri syndrome.CONCLUSION: Optic disc elevation and optic nerve sheath diameter are increased in new-onset pseudotumor cerebri syndrome. Optic disc elevation achieved high specificity and excellent sensitivity for diagnosis of pseudotumor cerebri syndrome. Transorbital sonography (TOS) is a potential, non-invasive screening tool for pseudotumor cerebri syndrome in headache clinics.
AB - BACKGROUND: Our objective was to assess optic nerve sheath diameter (a marker of elevated intracranial pressure) and optic disc elevation (a marker of papilledema) in pseudotumor cerebri syndrome using transorbital sonography.METHODS: The study was a prospective case-control study. We included patients with new-onset pseudotumor cerebri syndrome and matched healthy controls. All had fundoscopy, lumbar puncture with opening pressure and transorbital sonography. Sonography was assessed by a blinded observer.RESULTS: We evaluated 45 patients and included 23 cases. We recruited 35 controls. Optic nerve sheath diameter was larger in pseudotumor cerebri syndrome compared to controls (6.3 ± 0.9 mm versus 5.0 ± 0.5 mm, p < 0.001) and so was optic disc elevation (0.9 ± 0.4 mm versus 0.4 ± 0.1 mm, p < 0.001). The optimal cut-off point for optic nerve sheath diameter was 6 mm with a sensitivity of 74% for prediction of pseudotumor cerebri syndrome and 68% for prediction of elevated opening pressure. Specificity was 94%. The optimal cut-off point for optic disc elevation was 0.6 mm. Sensitivity was 100% and specificity 83% for prediction of pseudotumor cerebri syndrome.CONCLUSION: Optic disc elevation and optic nerve sheath diameter are increased in new-onset pseudotumor cerebri syndrome. Optic disc elevation achieved high specificity and excellent sensitivity for diagnosis of pseudotumor cerebri syndrome. Transorbital sonography (TOS) is a potential, non-invasive screening tool for pseudotumor cerebri syndrome in headache clinics.
KW - diagnostic imaging
KW - intracranial pressure
KW - optic disk
KW - optic nerve
KW - Pseudotumor cerebri
KW - Optic Nerve/diagnostic imaging
KW - Papilledema/diagnosis
KW - Humans
KW - Pseudotumor Cerebri/complications
KW - Ultrasonography
KW - Case-Control Studies
UR - http://www.scopus.com/inward/record.url?scp=85129856596&partnerID=8YFLogxK
U2 - 10.1177/03331024221094293
DO - 10.1177/03331024221094293
M3 - Journal article
C2 - 35469442
VL - 42
SP - 1116
EP - 1126
JO - Cephalalgia
JF - Cephalalgia
SN - 0333-1024
IS - 11-12
ER -