Transesophageal Doppler reliably tracks changes in cardiac output in comparison with intermittent pulmonary artery thermodilution in cardiac surgery patients

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Objectively measured early physical activity after total hip or knee arthroplasty

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Cerebral oximetry during preoperative resuscitation in elderly patients with hip fracture: a prospective observational study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Elastografie in der Brustbildgebung

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. History and Latest Advances in Flow Estimation Technology: From 1-D in 2-D to 3-D in 4-D

    Publikation: Bidrag til tidsskriftKonferenceartikelForskningpeer review

  3. Pressure Difference Estimation in Carotid Bulbs using Vector Flow Imaging - A Phantom Study

    Publikation: Bidrag til tidsskriftKonferenceartikelForskningpeer review

Vis graf over relationer

In this study a comparison of cardiac output (CO) measurements obtained with CardioQ transesophageal Doppler (TED) and pulmonary artery catheter (PAC) thermodilution (TD) technique was done in a systematic set-up, with induced changes in preload, afterload and heart rate. Twenty-five patients completed the study. Each patient were placed in the following successive positions: (1) supine, (2) head-down tilt, (3) head-up tilt, (4) supine, (5) supine with phenylephrine administration, (6) pace heart rate 80 beats per minute (bpm), (7) pace heart rate 110 bpm. The agreement of compared data was investigated by Bland-Altman plots, and to assess trending ability a four quadrants plot and a polar plot were constructed. Both methods showed an acceptable precision 6.4 % (PAC TD) and 12.8 % (TED). In comparison with PAC TD, the TED was associated with a mean bias in supine position of -0.30 l min(-1) (95 % CI -0.88; 0.27), wide limits of agreement, a percentage error of 69.5 %, and a trending ability with a concordance rate of 92 %, angular bias of 1.1° and a radial sector size of 40.0° corresponding to an acceptable trending ability. In comparison with PAC TD, the CardioQ TED showed a low mean bias, wide limits of agreement and a larger percentage error than should be expected from the precision of the two methods. However, an acceptable trending ability was found. Thus, the CardioQ TED should not replace CO measurements done by PAC TD, but could be a valuable tool in guiding therapy.

OriginalsprogEngelsk
TidsskriftJournal of Clinical Monitoring and Computing
Vol/bind31
Sider (fra-til)135-42
ISSN1387-1307
DOI
StatusUdgivet - 2017

ID: 45967108