Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Tissue to plasma capillary permeability of 131I-albumin in the perfused rabbit ear

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Capillary permeability of 131I-albumin in canine myocardium as determined by bolus injection, residue detection

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Plasma disappearance of tracer albumin and lymph flow

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Memorial. William Perl, 1918-1976

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Atrial fibrillation is a marker of increased mortality risk in non-ischemic heart failure - results from the DANISH Trial

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Reply to: TFC ECG in arrhythmogenic cardiomyopathy: Inadequate mixture of criteria?

    Publikation: Bidrag til tidsskriftLetterForskningpeer review

Vis graf over relationer

The tissue to plasma transfer of 131I-albumin was recorded in perfused rabbit ears (n = 6) following equilibration for 24 hr. 125I-fibrinogen served as the plasma marker, and was introduced intravenously 15 min before clamping. The ears were rollerpump perfused with isotonic diluted plasma at a constant rate of (mean +/- SD) 5.1 +/- 1.5 ml (min.100 g)-1. The mean extravascular albumin distribution volume was 12.4 +/- 1.1 ml.100 g-1, and the fibrinogen volume (plasma volume in tissue) was 3.1 +/- 0.4 ml.100 g-1 as determined from biopsies of the contralateral ear. The initial transfer of albumin was marked, and occurred at rates corresponding to a unidirectional clearance (Cl(0)) of 0.068 +/- 0.012 ml (min.100 g)-1. However, with a reduction of mean interstitial albumin tracer content of no more than 4%, net transport decreased to reach slowly declining levels 5 to 10 times lower within 10 min of continued perfusion. The decrease was considered due to rapid exhaustion of a small interstitial pool of tracer immediately adjacent to the exchange vessel membrane, followed by an increasingly retarded outwash from more distant areas. The results suggest a bimodal structural resistance to albumin movement: a relatively low resistance in the capillary membrane, and a considerable restriction to albumin transport located within the interstitial space.

OriginalsprogEngelsk
TidsskriftMicrovascular Research
Vol/bind41
Udgave nummer2
Sider (fra-til)141-8
Antal sider8
ISSN0026-2862
StatusUdgivet - mar. 1991