Three-dimensional accelerated acquisition for hyperpolarized 13 C MR  with blipped stack-of-spirals and conjugate-gradient  SENSE

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. ActiveAxADD: Toward non-parametric and orientationally invariant axon diameter distribution mapping using PGSE

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Quantification of cerebral perfusion and cerebrovascular reserve using Turbo-QUASAR arterial spin labeling MRI

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Coil profile estimation strategies for parallel imaging with hyperpolarized 13 C MRI

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Gamma-aminobutyric acid edited echo-planar spectroscopic imaging (EPSI) with MEGA-sLASER at 7T

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Multi-site benchmarking of clinical 13C RF coils at 3T

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Brain Changes Induced by Electroconvulsive Therapy Are Broadly Distributed

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Coil profile estimation strategies for parallel imaging with hyperpolarized 13 C MRI

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Inductive measurement and encoding of k-space trajectories in MR raw data

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  • Rie B Olin
  • Juan Diego Sánchez-Heredia
  • Rolf F Schulte
  • Nikolaj Bøgh
  • Esben Søvsø Szocska Hansen
  • Christoffer Laustsen
  • Lars G Hanson
  • Jan H Ardenkjaer-Larsen
Vis graf over relationer

PURPOSE: To test a new parallel imaging strategy for acceleration of hyperpolarized 13 C MR acquisitions based on a 3D blipped stack-of-spirals trajectory and conjugate-gradient SENSE reconstruction with precalibrated sensitivities.

METHODS: The blipped stack-of-spirals trajectory was developed for an acceleration factor of 4, based on an undersampled stack-of-spirals with gradient blips during spiral readout. The trajectory was developed with volumetric coverage of a large FOV and with high spatial resolution. High temporal resolution was attained through spectral-spatial excitation and 4 excitations per volume. The blipped stack-of-spirals was evaluated in simulations and phantom experiments. Next, the method was evaluated for kidney and cardiac imaging in 2 separate healthy pigs.

RESULTS: Simulation and phantom results showed successful acquisition and reconstruction, but also revealed reconstruction challenges for certain locations and for wide signal sources. For the kidney experiment, the accelerated acquisition showed high similarity to 2 separately acquired fully sampled data sets with matched spatial and temporal resolution, respectively. For the cardiac experiment, the accelerated acquisition proved able to map each metabolite in 3 dimensions within a single cardiac cycle.

CONCLUSION: The proposed method demonstrated effective mapping of metabolism in both kidneys and the heart of healthy pigs. Limitations seen in phantom experiments, may be irrelevant for most clinical applications, but should be kept in mind as well as reconstruction challenges related to residual aliasing. All in all, we show that the blipped stack-of-spirals is a relevant parallel imaging method for hyperpolarized human imaging, facilitating better insights into metabolism compared with nonaccelerated acquisition.

OriginalsprogEngelsk
TidsskriftMagnetic Resonance in Medicine
Vol/bind84
Udgave nummer2
Sider (fra-til)519-534
Antal sider16
ISSN0740-3194
DOI
StatusUdgivet - aug. 2020

Bibliografisk note

© 2020 International Society for Magnetic Resonance in Medicine.

ID: 59121037