Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

The Variability of Translocator Protein Signal in Brain and Blood of Genotyped Healthy Humans Using In Vivo (123)I-CLINDE SPECT Imaging: A Test-Retest Study

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Early Postoperative 18F-FET PET/MRI for Pediatric Brain and Spinal Cord Tumors

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. PET/CT versus standard imaging for prediction of survival in patients with recurrent head and neck squamous cell carcinoma

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Predictive value of PET response combined with baseline metabolic tumor volume in peripheral T-cell lymphoma patients

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Characterization of the serotonin 2A receptor selective PET tracer (R)-[18F]MH.MZ in the human brain

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Radiosynthesis and preclinical evaluation of [11 C]Cimbi-701 - Towards the imaging of cerebral 5-HT7 receptors

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. The structure of the serotonin system: A PET imaging study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Diagnostic added value of electrical source imaging in presurgical evaluation of patients with epilepsy: A prospective study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

(123)I-CLINDE is a radiotracer developed for SPECT and targets the 18-kDa translocator protein (TSPO). TSPO is upregulated in glial cells and used as a measure of neuroinflammation in a variety of central nervous system diseases. The aim of this study was to examine the test-retest variability of (123)I-CLINDE binding in healthy subjects. Methods: SPECT scans were acquired over 90 min in 16 healthy controls (9 women, 8 mixed-affinity binders [MABs] and 8 high-affinity binders [HABs] twice with an interval of 35 ± 15 d). Arterial input functions were based on individual blood measurements in 8 subjects and a population-based approach in combination with individual whole-blood time-activity curves in the other 8 subjects. Seven brain volumes of interest were extracted and quantified by SUVs and by 2-tissue-compartment modeling for calculation of distribution volumes (VT). Test-retest variability was measured by percentage difference (PD), the absolute PD, intraclass correlation coefficient (ICC), and coefficient of variation. Results: The absolute PD of brain SUV and the VT had similar values. The ICC values were higher for VTs than for brain SUVs, which were both moderate to high; however, lower ICC values were observed when calculated separately for HABs and MABs. Test-retest reproducibility was higher in subjects with immediate centrifugation of blood samples. The population-based method efficiently recovered data with delayed centrifugation. The VT of a 49-y-old male HAB was 7.5 ± 1.4 mL/cm(3) compared with 4.6 ± 1.4 mL/cm(3) of a sex- and age-matched MAB. The SUVs of a 49-y-old male HAB and MAB were 1.03 ± 0.14 and 0.88 ± 0.15 g/mL, respectively. Conclusion: The test-retest reproducibility of (123)I-CLINDE is comparable or better than that reported for commonly used PET TSPO tracers. Because of the binding of (123)I-CLINDE to blood cells and peripheral tissues, SUV is not a sufficient surrogate of VT from 2-tissue-compartment modeling. The population-adjusted method has the potential to reduce the complexity of blood analyses of TSPO tracers.

OriginalsprogEngelsk
TidsskriftJournal of nuclear medicine : official publication, Society of Nuclear Medicine
Vol/bind58
Udgave nummer6
Sider (fra-til)989-995
Antal sider7
ISSN0161-5505
DOI
StatusUdgivet - jun. 2017

ID: 51536428