Abstract
Agarose beads, an activator of complement, were incubated with MRC-5 or He 9 fibroblast cell lines under serum-free conditions. The beads were tested for binding of anti-complement antibodies by flow cytometry with a FACS 440 using FITC-labelled anti-Ig detection antibodies. Controls consisted of co-cultured beads incubated with irrelevant antibody or albumin, beads maintained in cell cultures containing cycloheximide, and beads which were not exposed to cells. The histograms demonstrated positive staining with anti-C3c, -C5, -C7 and -C9, but not with anti-C6 and -C8. Flow cytometry with multiple histogram analysis confirmed that the differences between the positive curves and the controls were statistically significant. The results show that cell-derived complement components (C3, C5, C7 and C9) were deposited on the beads and could be detected by flow cytometry.
Originalsprog | Engelsk |
---|---|
Tidsskrift | Journal of Immunological Methods |
Vol/bind | 140 |
Udgave nummer | 2 |
Sider (fra-til) | 167-71 |
Antal sider | 5 |
ISSN | 0022-1759 |
DOI | |
Status | Udgivet - 5 jul. 1991 |
Udgivet eksternt | Ja |