title = "The response of a standardized fluid challenge during cardiac surgery on cerebral oxygen saturation measured with near-infrared spectroscopy",
abstract = "Near infrared spectroscopy (NIRS) has been used to evaluate regional cerebral tissue oxygen saturation (ScO2) during the last decades. Perioperative management algorithms advocate to maintain ScO2, by maintaining or increasing cardiac output (CO), e.g. with fluid infusion. We hypothesized that ScO2 would increase in responders to a standardized fluid challenge (FC) and that the relative changes in CO and ScO2 would correlate. This study is a retrospective substudy of the FLuid Responsiveness Prediction Using Extra Systoles (FLEX) trial. In the FLEX trial, patients were administered two standardized FCs (5 mL/kg ideal body weight each) during cardiac surgery. NIRS monitoring was used during the intraoperative period and CO was monitored continuously. Patients were considered responders if stroke volume increased more than 10% following FC. Datasets from 29 non-responders and 27 responders to FC were available for analysis. Relative changes of ScO2 did not change significantly in non-responders (mean difference - 0.3% ± 2.3%, p = 0.534) or in fluid responders (mean difference 1.6% ± 4.6%, p = 0.088). Relative changes in CO and ScO2 correlated significantly, p = 0.027. Increasing CO by fluid did not change cerebral oxygenation. Despite this, relative changes in CO correlated to relative changes in ScO2. However, the clinical impact of the present observations is unclear, and the results must be interpreted with caution.Trial registration: http://ClinicalTrial.gov identifier for main study (FLuid Responsiveness Prediction Using Extra Systoles-FLEX): NCT03002129.",
keywords = "Cardiac anaesthesia, Cardiac output, Cerebral oximetry, Fluid challenge, Monitoring, Near infrared spectroscopy",
author = "Frederik Holmgaard and Vistisen, {Simon T} and Ravn, {Hanne B} and Scheeren, {Thomas W L}",
year = "2020",
month = apr,
doi = "10.1007/s10877-019-00324-w",
language = "English",
volume = "34",
pages = "245--251",
journal = "Journal of Clinical Monitoring and Computing",
issn = "1387-1307",
publisher = "Springer Netherlands",
number = "2",

}

RIS

TY - JOUR

T1 - The response of a standardized fluid challenge during cardiac surgery on cerebral oxygen saturation measured with near-infrared spectroscopy

AU - Holmgaard, Frederik

AU - Vistisen, Simon T

AU - Ravn, Hanne B

AU - Scheeren, Thomas W L

PY - 2020/4

Y1 - 2020/4

N2 - Near infrared spectroscopy (NIRS) has been used to evaluate regional cerebral tissue oxygen saturation (ScO2) during the last decades. Perioperative management algorithms advocate to maintain ScO2, by maintaining or increasing cardiac output (CO), e.g. with fluid infusion. We hypothesized that ScO2 would increase in responders to a standardized fluid challenge (FC) and that the relative changes in CO and ScO2 would correlate. This study is a retrospective substudy of the FLuid Responsiveness Prediction Using Extra Systoles (FLEX) trial. In the FLEX trial, patients were administered two standardized FCs (5 mL/kg ideal body weight each) during cardiac surgery. NIRS monitoring was used during the intraoperative period and CO was monitored continuously. Patients were considered responders if stroke volume increased more than 10% following FC. Datasets from 29 non-responders and 27 responders to FC were available for analysis. Relative changes of ScO2 did not change significantly in non-responders (mean difference - 0.3% ± 2.3%, p = 0.534) or in fluid responders (mean difference 1.6% ± 4.6%, p = 0.088). Relative changes in CO and ScO2 correlated significantly, p = 0.027. Increasing CO by fluid did not change cerebral oxygenation. Despite this, relative changes in CO correlated to relative changes in ScO2. However, the clinical impact of the present observations is unclear, and the results must be interpreted with caution.Trial registration: http://ClinicalTrial.gov identifier for main study (FLuid Responsiveness Prediction Using Extra Systoles-FLEX): NCT03002129.

AB - Near infrared spectroscopy (NIRS) has been used to evaluate regional cerebral tissue oxygen saturation (ScO2) during the last decades. Perioperative management algorithms advocate to maintain ScO2, by maintaining or increasing cardiac output (CO), e.g. with fluid infusion. We hypothesized that ScO2 would increase in responders to a standardized fluid challenge (FC) and that the relative changes in CO and ScO2 would correlate. This study is a retrospective substudy of the FLuid Responsiveness Prediction Using Extra Systoles (FLEX) trial. In the FLEX trial, patients were administered two standardized FCs (5 mL/kg ideal body weight each) during cardiac surgery. NIRS monitoring was used during the intraoperative period and CO was monitored continuously. Patients were considered responders if stroke volume increased more than 10% following FC. Datasets from 29 non-responders and 27 responders to FC were available for analysis. Relative changes of ScO2 did not change significantly in non-responders (mean difference - 0.3% ± 2.3%, p = 0.534) or in fluid responders (mean difference 1.6% ± 4.6%, p = 0.088). Relative changes in CO and ScO2 correlated significantly, p = 0.027. Increasing CO by fluid did not change cerebral oxygenation. Despite this, relative changes in CO correlated to relative changes in ScO2. However, the clinical impact of the present observations is unclear, and the results must be interpreted with caution.Trial registration: http://ClinicalTrial.gov identifier for main study (FLuid Responsiveness Prediction Using Extra Systoles-FLEX): NCT03002129.

KW - Cardiac anaesthesia

KW - Cardiac output

KW - Cerebral oximetry

KW - Fluid challenge

KW - Monitoring

KW - Near infrared spectroscopy

U2 - 10.1007/s10877-019-00324-w

DO - 10.1007/s10877-019-00324-w

M3 - Journal article

C2 - 31134474

VL - 34

SP - 245

EP - 251

JO - Journal of Clinical Monitoring and Computing

JF - Journal of Clinical Monitoring and Computing

SN - 1387-1307

IS - 2