Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

The feasibility of tricuspid annular plane systolic excursion performed by transesophageal echocardiography throughout heart surgery and its interchangeability with transthoracic echocardiography

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Accelerated treatment of endocarditis-The POET II trial: Rationale and design of a randomized controlled trial

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Long-term Survival and Cognitive Function According to Blood Pressure Management During Cardiac Surgery. A Follow-up

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Intravascular Microaxial Left Ventricular Assist Device vs Intra-aortic Balloon Pump for Cardiogenic Shock

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Age-specific trends in incidence and survival of out-of-hospital cardiac arrest from presumed cardiac cause in Denmark 2002-2014

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. Valve regurgitation in patients surviving endocarditis and the subsequent risk of heart failure

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

Tricuspid annular plane systolic excursion (TAPSE) is a robust measure of RV function, but the performance of transesophageal echocardiography (TEE) measured TAPSE during surgery is not well established. We aim to evaluate feasibility of various TEE views before, during and after surgery. Furthermore, we compare performance of individual TEE measurements depending on view and method (AMM- and M-mode as well as 2D) as well as TAPSE measured using TEE with transthoracic echocardiography (TTE) TAPSE. The study was conducted from January 2015 through September 2016. In 47 patients with normal left ventricular ejection fraction, TEE was prospectively performed during coronary artery bypass grafting surgery. TAPSE and tricuspid annulus tissue Doppler imaging (TDI) were recorded in five different views at pre-specified time points during surgery. Data were analyzed for availability (obtainable/readable images) and reliability (intra-/inter-observer bias and precision). Finally, TEE TAPSE was compared to TTE TAPSE immediately before and after surgery. TAPSE and TDI with TEE was achievable in > 90% of patients in the transgastric view during surgery. The AM- and M-mode had the best reliability and the best correlation with TAPSE measured with TTE. The deep transgastric view was achievable in less than 50% after sternotomy, and TAPSE measured from 2D had a poorer performance compared to the AM- and M-mode. TDI demonstrated a high reliability throughout surgery. RV function can be evaluated by TAPSE and TDI using TEE during surgery. TEE values from the transgastric view demonstrated high performance throughout surgery and a good agreement with TTE TAPSE measurements.

OriginalsprogEngelsk
TidsskriftThe international journal of cardiovascular imaging
Vol/bind34
Udgave nummer7
Sider (fra-til)1017-1028
Antal sider12
ISSN1569-5794
DOI
StatusUdgivet - 2018