Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

The efficacy of using computer-aided detection (CAD) for detection of breast cancer in mammography screening: a systematic review

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Grading lumbar disc degeneration: a comparison between low- and high-field MRI

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. The effects of rotation on radiological parameters in the spine

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. New section editor: Cardiac Imaging

    Publikation: Bidrag til tidsskriftTidsskriftartikelFormidling

  4. Arterial spin labeling: a technical overview

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  1. Electroconvulsive therapy increases cortical thickness in depression

    Publikation: KonferencebidragPosterForskning

  2. Electroconvulsive therapy increases cortical thickness in depression

    Publikation: KonferencebidragPosterForskning

  3. Portable Vector Flow Imaging Compared with Spectral Doppler Ultrasonography

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Pediatric Transthoracic Cardiac Vector Flow Imaging - A Preliminary Pictorial Study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. Automatic Detection of B-lines in In-Vivo Lung Ultrasound

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

Background Early detection of breast cancer (BC) is crucial in lowering the mortality. Purpose To present an overview of studies concerning computer-aided detection (CAD) in screening mammography for early detection of BC and compare diagnostic accuracy and recall rates (RR) of single reading (SR) with SR + CAD and double reading (DR) with SR + CAD. Material and Methods PRISMA guidelines were used as a review protocol. Articles on clinical trials concerning CAD for detection of BC in a screening population were included. The literature search resulted in 1522 records. A total of 1491 records were excluded by abstract and 18 were excluded by full text reading. A total of 13 articles were included. Results All but two studies from the SR vs. SR + CAD group showed an increased sensitivity and/or cancer detection rate (CDR) when adding CAD. The DR vs. SR + CAD group showed no significant differences in sensitivity and CDR. Adding CAD to SR increased the RR and decreased the specificity in all but one study. For the DR vs. SR + CAD group only one study reported a significant difference in RR. Conclusion All but two studies showed an increase in RR, sensitivity and CDR when adding CAD to SR. Compared to DR no statistically significant differences in sensitivity or CDR were reported. Additional studies based on organized population-based screening programs, with longer follow-up time, high-volume readers, and digital mammography are needed to evaluate the efficacy of CAD.

OriginalsprogEngelsk
TidsskriftActa Radiologica
Vol/bind60
Udgave nummer1
Sider (fra-til)13-18
ISSN0284-1851
DOI
StatusUdgivet - 2019

ID: 54645650