The effect of personalized versus standard patient protocols for radiostereometric analysis (RSA)

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Harvard

APA

CBE

MLA

Vancouver

Author

Bibtex

@article{7a51958c8cec46149d48c699eca19c9f,
title = "The effect of personalized versus standard patient protocols for radiostereometric analysis (RSA)",
abstract = "INTRODUCTION: Increasing pressure in the clinic requires a more standardized approach to radiostereometric analysis (RSA) imaging. The aim of this study was to investigate whether implementation of personalized RSA patient protocols could increase image quality and decrease examination time and the number of exposure repetitions.METHODS: Forty patients undergoing primary total hip arthroplasty were equally randomized to either a case or a control group. Radiographers in the case group were assisted by personalized patient protocols containing information about each patient's post-operative RSA imaging. Radiographers in the control group used a standard RSA protocol.RESULTS: At three months, radiographers in the case group significantly reduced (p < 0.001) the number of exposures by 1.6, examination time with 19.2 min, and distance between centrum of prosthesis and centrum of calibration field with 34.1 mm when compared to post-operative (baseline) results. At twelve months, the case group significantly reduced (p < 0.001) number of exposures by two, examination time with 22.5 min, and centrum of prosthesis to centrum of calibration field distance with 43.1 mm when compared to baseline results. No significant improvements were found in the control group at any time point.CONCLUSION: There is strong evidence that personalized RSA patient protocols have a positive effect on image quality and radiation dose savings. Implementation of personal patient protocols as a RSA standard will contribute to the reduction of examination time, thus ensuring a cost benefit for department and patient safety.",
author = "O Muharemovic and A Troelsen and Thomsen, {M G} and T Kallemose and Gosvig, {K K}",
note = "Copyright {\circledC} 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.",
year = "2018",
month = "5",
day = "1",
doi = "10.1016/j.radi.2017.11.006",
language = "English",
volume = "24",
pages = "e31--e36",
journal = "Radiography",
issn = "1078-8174",
publisher = "W.B. Saunders Ltd",
number = "2",

}

RIS

TY - JOUR

T1 - The effect of personalized versus standard patient protocols for radiostereometric analysis (RSA)

AU - Muharemovic, O

AU - Troelsen, A

AU - Thomsen, M G

AU - Kallemose, T

AU - Gosvig, K K

N1 - Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

PY - 2018/5/1

Y1 - 2018/5/1

N2 - INTRODUCTION: Increasing pressure in the clinic requires a more standardized approach to radiostereometric analysis (RSA) imaging. The aim of this study was to investigate whether implementation of personalized RSA patient protocols could increase image quality and decrease examination time and the number of exposure repetitions.METHODS: Forty patients undergoing primary total hip arthroplasty were equally randomized to either a case or a control group. Radiographers in the case group were assisted by personalized patient protocols containing information about each patient's post-operative RSA imaging. Radiographers in the control group used a standard RSA protocol.RESULTS: At three months, radiographers in the case group significantly reduced (p < 0.001) the number of exposures by 1.6, examination time with 19.2 min, and distance between centrum of prosthesis and centrum of calibration field with 34.1 mm when compared to post-operative (baseline) results. At twelve months, the case group significantly reduced (p < 0.001) number of exposures by two, examination time with 22.5 min, and centrum of prosthesis to centrum of calibration field distance with 43.1 mm when compared to baseline results. No significant improvements were found in the control group at any time point.CONCLUSION: There is strong evidence that personalized RSA patient protocols have a positive effect on image quality and radiation dose savings. Implementation of personal patient protocols as a RSA standard will contribute to the reduction of examination time, thus ensuring a cost benefit for department and patient safety.

AB - INTRODUCTION: Increasing pressure in the clinic requires a more standardized approach to radiostereometric analysis (RSA) imaging. The aim of this study was to investigate whether implementation of personalized RSA patient protocols could increase image quality and decrease examination time and the number of exposure repetitions.METHODS: Forty patients undergoing primary total hip arthroplasty were equally randomized to either a case or a control group. Radiographers in the case group were assisted by personalized patient protocols containing information about each patient's post-operative RSA imaging. Radiographers in the control group used a standard RSA protocol.RESULTS: At three months, radiographers in the case group significantly reduced (p < 0.001) the number of exposures by 1.6, examination time with 19.2 min, and distance between centrum of prosthesis and centrum of calibration field with 34.1 mm when compared to post-operative (baseline) results. At twelve months, the case group significantly reduced (p < 0.001) number of exposures by two, examination time with 22.5 min, and centrum of prosthesis to centrum of calibration field distance with 43.1 mm when compared to baseline results. No significant improvements were found in the control group at any time point.CONCLUSION: There is strong evidence that personalized RSA patient protocols have a positive effect on image quality and radiation dose savings. Implementation of personal patient protocols as a RSA standard will contribute to the reduction of examination time, thus ensuring a cost benefit for department and patient safety.

U2 - 10.1016/j.radi.2017.11.006

DO - 10.1016/j.radi.2017.11.006

M3 - Journal article

VL - 24

SP - e31-e36

JO - Radiography

JF - Radiography

SN - 1078-8174

IS - 2

ER -

ID: 54176832