The effect of intermittent atrial tachyarrhythmia on heart failure or death in cardiac resynchronization therapy with defibrillator versus implantable cardioverter-defibrillator patients: a MADIT-CRT substudy (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy)

Anne-Christine Ruwald, Grzegorz Pietrasik, Ilan Goldenberg, Valentina Kutyifa, Martin H Ruwald, Christian Jons, Scott McNitt, Paul Wang, Wojciech Zareba, Arthur J Moss

28 Citationer (Scopus)

Abstract

OBJECTIVES: This study aimed to investigate the effect of both history of intermittent atrial tachyarrhythmias (IAT) and in-trial IAT on the risk of heart failure (HF) or death comparing cardiac resynchronization therapy with defibrillator (CRT-D) to implantable cardioverter-defibrillator (ICD) treatment in mildly symptomatic HF patients with left bundle branch block (LBBB).

BACKGROUND: Limited data exist regarding the benefit of CRT-D in patients with IAT.

METHODS: The benefit of CRT-D in reducing the risk of HF/death was evaluated using multivariate Cox models incorporating the presence of, respectively, a history of IAT at baseline and time-dependent development of in-trial IAT during follow-up in 1,264 patients with LBBB enrolled in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) study.

RESULTS: The overall beneficial effect of CRT-D versus ICD on the risk of HF/death was not significantly different between LBBB patients with or without history of IAT (HR: 0.50, p = 0.028, and HR: 0.46, p < 0.001, respectively; p for interaction = 0.79). Among patients who had in-trial IAT, CRT-D was associated with a significant 57% reduction in the risk of HF/death compared with ICD-only therapy (HR: 0.43, p = 0.047), similar to the effect of the device among patients who did not have IAT (HR: 0.47, p < 0.001; p for interaction = 0.85). The percentage of patients with biventricular pacing ≥92% was similar in both groups (p = 0.43). Consistent results were shown for the benefit of CRT-D among patients who had in-trial atrial fibrillation/flutter (HR: 0.30, p = 0.027; p for interaction = 0.41).

CONCLUSIONS: In the MADIT-CRT study, the clinical benefit of CRT-D in LBBB patients was not attenuated by prior history of IAT or by the development of in-trial atrial tachyarrhythmias. (MADIT-CRT: Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy; NCT00180271).

OriginalsprogEngelsk
TidsskriftJournal of the American College of Cardiology
Vol/bind63
Udgave nummer12
Sider (fra-til)1190-7
Antal sider8
ISSN0735-1097
DOI
StatusUdgivet - 1 apr. 2014

Fingeraftryk

Dyk ned i forskningsemnerne om 'The effect of intermittent atrial tachyarrhythmia on heart failure or death in cardiac resynchronization therapy with defibrillator versus implantable cardioverter-defibrillator patients: a MADIT-CRT substudy (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy)'. Sammen danner de et unikt fingeraftryk.

Citationsformater