TY - JOUR
T1 - The Dimensions of the Orbital Cavity Based on High-Resolution Computed Tomography of Human Cadavers
AU - Felding, Ulrik Ascanius
AU - Bloch, Sune Land
AU - Buchwald, Christian von
PY - 2016/6
Y1 - 2016/6
N2 - Blow-out fractures affect the volume and surface area of the orbital cavity. Estimation of these values after the trauma may help in deciding whether or not a patient is a candidate for surgery. Recent studies have provided estimates of orbital volume and area of bone defect, and correlated them with the degree of enophthalmos. However, a large degree of biological variation between individuals may preclude such absolute values from being successful indicators for surgery.Stereological methods have been used to estimate orbital cavity volume in a few studies, but to date these have not been used for surface area. To authors' knowledge, this study is the first to have measured the entire surface area of the orbital cavity.The volume and surface area of the orbital cavity were estimated in computed tomography scans of 11 human cadavers using unbiased stereological sampling techniques. The mean (± SD) total volume and total surface area of the orbital cavities was 24.27 ± 3.88 cm and 32.47 ± 2.96 cm, respectively. There was no significant difference in volume (P = 0.315) or surface area (P = 0.566) between the 2 orbital cavities.The stereological technique proved to be a robust and unbiased method that may be used as a gold standard for comparison with automated computer software. Future imaging studies in blow-out fracture patients may be based on individual and relative calculation involving both herniated volume and fractured surface area in relation to the total volume and surface area of the uninjured orbital cavity.
AB - Blow-out fractures affect the volume and surface area of the orbital cavity. Estimation of these values after the trauma may help in deciding whether or not a patient is a candidate for surgery. Recent studies have provided estimates of orbital volume and area of bone defect, and correlated them with the degree of enophthalmos. However, a large degree of biological variation between individuals may preclude such absolute values from being successful indicators for surgery.Stereological methods have been used to estimate orbital cavity volume in a few studies, but to date these have not been used for surface area. To authors' knowledge, this study is the first to have measured the entire surface area of the orbital cavity.The volume and surface area of the orbital cavity were estimated in computed tomography scans of 11 human cadavers using unbiased stereological sampling techniques. The mean (± SD) total volume and total surface area of the orbital cavities was 24.27 ± 3.88 cm and 32.47 ± 2.96 cm, respectively. There was no significant difference in volume (P = 0.315) or surface area (P = 0.566) between the 2 orbital cavities.The stereological technique proved to be a robust and unbiased method that may be used as a gold standard for comparison with automated computer software. Future imaging studies in blow-out fracture patients may be based on individual and relative calculation involving both herniated volume and fractured surface area in relation to the total volume and surface area of the uninjured orbital cavity.
KW - Journal Article
U2 - 10.1097/SCS.0000000000002604
DO - 10.1097/SCS.0000000000002604
M3 - Journal article
C2 - 27171949
SN - 1049-2275
VL - 27
SP - 1090
EP - 1093
JO - The Journal of craniofacial surgery
JF - The Journal of craniofacial surgery
IS - 4
ER -