TY - JOUR
T1 - Test-retest reliability of transfer function analysis metrics for assessing dynamic cerebral autoregulation to spontaneous blood pressure oscillations
AU - Olsen, Markus Harboe
AU - Riberholt, Christian
AU - Capion, Tenna
AU - Plovsing, Ronni R
AU - Møller, Kirsten
AU - Berg, Ronan M G
N1 - © 2024 The Authors. Experimental Physiology published by John Wiley & Sons Ltd on behalf of The Physiological Society.
PY - 2024/7
Y1 - 2024/7
N2 - Transfer function analysis (TFA) is a widely used method for assessing dynamic cerebral autoregulation in humans. In the present study, we assessed the test-retest reliability of established TFA metrics derived from spontaneous blood pressure oscillations and based on 5 min recordings. The TFA-based gain, phase and coherence in the low-frequency range (0.07-0.20 Hz) from 19 healthy volunteers, 37 patients with subarachnoid haemorrhage and 19 patients with sepsis were included. Reliability assessments included the smallest real difference (SRD) and the coefficient of variance for comparing consecutive 5 min recordings, temporally separated 5 min recordings and consecutive recordings with a minimal length of 10 min. In healthy volunteers, temporally separating the 5 min recordings led to a 0.38 (0.01-0.79) cm s-1 mmHg-1 higher SRD for gain (P = 0.032), and extending the duration of recordings did not affect the reliability. In subarachnoid haemorrhage, temporal separation led to a 0.85 (-0.13 to 1.93) cm s-1 mmHg-1 higher SRD (P = 0.047) and a 20 (-2 to 41)% higher coefficient of variance (P = 0.038) for gain, but neither metric was affected by extending the recording duration. In sepsis, temporal separation increased the SRD for phase by 94 (23-160)° (P = 0.006) but was unaffected by extending the recording. A recording duration of 8 min was required to achieve stable gain and normalized gain measures in healthy individuals, and even longer recordings were required in patients. In conclusion, a recording duration of 5 min appears insufficient for obtaining stable and reliable TFA metrics when based on spontaneous blood pressure oscillations, particularly in critically ill patients with subarachnoid haemorrhage and sepsis.
AB - Transfer function analysis (TFA) is a widely used method for assessing dynamic cerebral autoregulation in humans. In the present study, we assessed the test-retest reliability of established TFA metrics derived from spontaneous blood pressure oscillations and based on 5 min recordings. The TFA-based gain, phase and coherence in the low-frequency range (0.07-0.20 Hz) from 19 healthy volunteers, 37 patients with subarachnoid haemorrhage and 19 patients with sepsis were included. Reliability assessments included the smallest real difference (SRD) and the coefficient of variance for comparing consecutive 5 min recordings, temporally separated 5 min recordings and consecutive recordings with a minimal length of 10 min. In healthy volunteers, temporally separating the 5 min recordings led to a 0.38 (0.01-0.79) cm s-1 mmHg-1 higher SRD for gain (P = 0.032), and extending the duration of recordings did not affect the reliability. In subarachnoid haemorrhage, temporal separation led to a 0.85 (-0.13 to 1.93) cm s-1 mmHg-1 higher SRD (P = 0.047) and a 20 (-2 to 41)% higher coefficient of variance (P = 0.038) for gain, but neither metric was affected by extending the recording duration. In sepsis, temporal separation increased the SRD for phase by 94 (23-160)° (P = 0.006) but was unaffected by extending the recording. A recording duration of 8 min was required to achieve stable gain and normalized gain measures in healthy individuals, and even longer recordings were required in patients. In conclusion, a recording duration of 5 min appears insufficient for obtaining stable and reliable TFA metrics when based on spontaneous blood pressure oscillations, particularly in critically ill patients with subarachnoid haemorrhage and sepsis.
KW - Adult
KW - Aged
KW - Blood Pressure/physiology
KW - Cerebrovascular Circulation/physiology
KW - Female
KW - Homeostasis/physiology
KW - Humans
KW - Male
KW - Middle Aged
KW - Reproducibility of Results
KW - Sepsis/physiopathology
KW - Subarachnoid Hemorrhage/physiopathology
KW - Young Adult
KW - transcranial Doppler ultrasound
KW - subarachnoid haemorrhage
KW - physiolometrics
KW - sepsis
UR - http://www.scopus.com/inward/record.url?scp=85190465586&partnerID=8YFLogxK
U2 - 10.1113/EP091500
DO - 10.1113/EP091500
M3 - Journal article
C2 - 38590228
SN - 0958-0670
VL - 109
SP - 1024
EP - 1039
JO - Experimental Physiology
JF - Experimental Physiology
IS - 7
ER -