TY - JOUR
T1 - Super-Resolution Ultrasound Imaging Using the Erythrocytes-Part II
T2 - Velocity Images
AU - Naji, Mostafa Amin
AU - Taghavi, Iman
AU - Schou, Mikkel
AU - Praesius, Sebastian Kazmarek
AU - Hansen, Lauge Naur
AU - Panduro, Nathalie Sarup
AU - Andersen, Sofie Bech
AU - Sogaard, Stinne Byrholdt
AU - Gundlach, Carsten
AU - Kjer, Hans Martin
AU - Tomov, Borislav Gueorguiev
AU - Thomsen, Erik Vilain
AU - Nielsen, Michael Bachmann
AU - Larsen, Niels Bent
AU - Dahl, Anders Bjorholm
AU - Sorensen, Charlotte Mehlin
AU - Jensen, Jorgen Arendt
PY - 2024/8
Y1 - 2024/8
N2 - Super-resolution ultrasound imaging using the erythrocytes (SURE) has recently been introduced. The method uses erythrocytes as targets instead of fragile microbubbles (MBs). The abundance of erythrocyte scatterers makes it possible to acquire SURE data in just a few seconds compared with several minutes in ultrasound localization microscopy (ULM) using MBs. A high number of scatterers can reduce the acquisition time; however, the tracking of uncorrelated and high-density scatterers is quite challenging. This article hypothesizes that it is possible to detect and track erythrocytes as targets to obtain vascular flow images. A SURE tracking pipeline is used with modules for beamforming, recursive synthetic aperture (SA) imaging, motion estimation, echo canceling, peak detection, and recursive nearest-neighbor (NN) tracker. The SURE tracking pipeline is capable of distinguishing the flow direction and separating tubes of a simulated Field II phantom with 125-25- [Formula: see text] wall-to-wall tube distances, as well as a 3-D printed hydrogel micr-flow phantom with 100-60- [Formula: see text] wall-to-wall channel distances. The comparison of an in vivo SURE scan of a Sprague-Dawley rat kidney with ULM and micro-computed tomography (CT) scans with voxel sizes of 26.5 and [Formula: see text] demonstrated consistent findings. A microvascular structure composed of 16 vessels exhibited similarities across all imaging modalities. The flow direction and velocity profiles in the SURE scan were found to be concordant with those from ULM.
AB - Super-resolution ultrasound imaging using the erythrocytes (SURE) has recently been introduced. The method uses erythrocytes as targets instead of fragile microbubbles (MBs). The abundance of erythrocyte scatterers makes it possible to acquire SURE data in just a few seconds compared with several minutes in ultrasound localization microscopy (ULM) using MBs. A high number of scatterers can reduce the acquisition time; however, the tracking of uncorrelated and high-density scatterers is quite challenging. This article hypothesizes that it is possible to detect and track erythrocytes as targets to obtain vascular flow images. A SURE tracking pipeline is used with modules for beamforming, recursive synthetic aperture (SA) imaging, motion estimation, echo canceling, peak detection, and recursive nearest-neighbor (NN) tracker. The SURE tracking pipeline is capable of distinguishing the flow direction and separating tubes of a simulated Field II phantom with 125-25- [Formula: see text] wall-to-wall tube distances, as well as a 3-D printed hydrogel micr-flow phantom with 100-60- [Formula: see text] wall-to-wall channel distances. The comparison of an in vivo SURE scan of a Sprague-Dawley rat kidney with ULM and micro-computed tomography (CT) scans with voxel sizes of 26.5 and [Formula: see text] demonstrated consistent findings. A microvascular structure composed of 16 vessels exhibited similarities across all imaging modalities. The flow direction and velocity profiles in the SURE scan were found to be concordant with those from ULM.
KW - Erythrocytes
KW - Ultrasonography/methods
KW - Animals
KW - Phantoms, Imaging
KW - Rats
KW - Image Processing, Computer-Assisted/methods
KW - Algorithms
KW - Blood Flow Velocity/physiology
KW - Rats, Sprague-Dawley
UR - http://www.scopus.com/inward/record.url?scp=85196076724&partnerID=8YFLogxK
U2 - 10.1109/TUFFC.2024.3411795
DO - 10.1109/TUFFC.2024.3411795
M3 - Journal article
C2 - 38857146
SN - 0885-3010
VL - 71
SP - 945
EP - 959
JO - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
JF - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
IS - 8
ER -