Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Snaring of a Glued Microcatheter During Embolization of an Arteriovenous Malformation with N-Butyl Cyanoacrylate

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Dural Arteriovenous Fistula of the Vein of Trolard Mimicking a Cavernous Sinus Fistula

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Biopsy and Ablation of H3K27 Glioma Using Skull-Mounted Smartframe Device: Technical Case Report

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Comparison of Frame-Based Versus Frameless Intracranial Stereotactic Biopsy: Systematic Review and Meta-Analysis

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  4. Deciding on Appropriate Telemetric Intracranial Pressure Monitoring System

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Dural Arteriovenous Fistula of the Vein of Trolard Mimicking a Cavernous Sinus Fistula

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Transcerebral exchange kinetics of large neutral amino acids during acute inspiratory hypoxia in humans

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Subdural contrast effusion during endovascular therapy: case report

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Vector Concentration used for Stenosis Assessment in the Carotid Artery before and after Carotid Stenting

    Publikation: Bidrag til tidsskriftKonferenceartikelForskningpeer review

Vis graf over relationer

BACKGROUND: Microcatheter entrapment during embolization of brain arteriovenous malformations (AVMs) represents a potentially harmful technical complication. Although several techniques have been reported for endovascular catheter retrieval from an Onyx cast, such methods have never been demonstrated with acrylic glues. We report a case of removal of a glued microcatheter from an N-butyl cyanoacrylate (NBCA) cast using a microsnare.

METHODS AND RESULTS: A 26-year-old woman presented with an intracranial hemorrhage resulting from a ruptured right choroidal AVM. A microcatheter used for transarterial embolization was unintentionally glued into the NBCA cast. Because attempts to remove the catheter by simple traction failed, a microsnare was used and allowed withdrawal of the entrapped microcatheter without causing damage to the cerebral vasculature. The patient woke up without clinical sequelae.

CONCLUSIONS: Although it is not recommended as routine practice, snaring a glued microcatheter is feasible and can be used in selected cases as a last resort if thromboembolic complications are feared.