Single- and dual-energy quantitative CT adjacent to acetabular prosthetic components: a reliability study

Publikation: Bidrag til tidsskriftKonferenceabstrakt i tidsskriftpeer review

DOI

  1. Features of infective native aortic aneurysms on computed tomography

    Publikation: Bidrag til tidsskriftTidsskriftartikelpeer review

  2. The role of lung ultrasound in COVID-19 disease

    Publikation: Bidrag til tidsskriftTidsskriftartikelpeer review

  3. How to diagnose acute appendicitis: ultrasound first

    Publikation: Bidrag til tidsskriftTidsskriftartikelpeer review

  4. Imaging patients with renal colic-consider ultrasound first

    Publikation: Bidrag til tidsskriftTidsskriftartikelpeer review

Vis graf over relationer
Purpose: Density measurements adjacent to acetabular prosthetic components are challenged by artifacts and the complex anatomy. Three-dimensional ROIs are needed to assess the bone stock. The purpose was to test the intraobserver agreement and reliability of custom segmentation software and to compare BMD measurements in single and dual energy CT (SECT and DECT). Methods and Materials: 10 male patients with uncemented hip prosthetics were scanned and rescanned using 120 kVp SECT and DECT with virtual monochromatic images reconstructed at 130 keV. Hemispherical ROIs were defined slice-by-slice and bone mineral density was calculated using a calibration phantom. Median time between ROI drawings was 6 days. Results: The mean BMD for repeated SECT scans was 430 mg/ccm with a between scan difference of 18 mg/ccm, p=0.001. ICC was 0.98 (95%CI: 0.73 to 1). For DECT the mean BMD was 162 mg/ccm with a difference of 11 mg/ccm, p<0.0001. ICC was 0.94 (95%CI: 0.36 to 0.99). Bland-Altman Limits of Agreement were -51 to 15 in SECT and -30 to 7 in DECT. Repeatability coefficients were 33 and 18 mg/ccm for SECT and DECT respectively. The difference was not statistically significant. Conclusion: The intraobserver reliability was high for both scan modes with statistically significant differences between the repeated measurements in SECT and DECT. The limits of agreement were slightly narrower in DECT, but with no statistically significant difference between repeatability coefficients. The results suggest that the intraobserver agreement of the scan modes is equal. BMD cannot be measured interchangeably with SECT and DECT.
OriginalsprogEngelsk
ArtikelnummerB-0141
TidsskriftInsights into Imaging
Vol/bind8
Udgave nummerSuppl. 1
Sider (fra-til)212
Antal sider1
ISSN1869-4101
DOI
StatusUdgivet - mar. 2017
Eksternt udgivetJa
BegivenhedEuropean Congress of Radiology - Wien, Østrig
Varighed: 1 mar. 20175 mar. 2017

Konference

KonferenceEuropean Congress of Radiology
LandØstrig
ByWien
Periode01/03/201705/03/2017

Begivenhed

European Congress of Radiology

01/03/201705/03/2017

Wien, Østrig

Begivenhed: Konference

ID: 66053238