Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Risk of fetal loss associated with invasive testing following combined first-trimester screening for Down syndrome: a national cohort of 147 987 singleton pregnancies

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Fetal Costello syndrome: description of phenotype of HRAS exon 1 mutations

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Neurodevelopmental disorder in children believed to have isolated mild ventriculomegaly prenatally

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Fetal fraction of cell-free DNA in pregnancies after fresh or frozen embryo transfer following assisted reproductive technologies

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. "It's probably nothing, but…" Couples' experiences of pregnancy following an uncertain prenatal genetic result

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Current use of noninvasive prenatal testing in Europe, Australia and the USA: A graphical presentation

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

OBJECTIVE: To assess prospectively the risk of fetal loss associated with chorionic villus sampling (CVS) and amniocentesis (AC) following combined first-trimester screening (cFTS) for Down syndrome.

METHODS: This was a nationwide population-based study (Danish Fetal Medicine Database, 2008-2010) including 147 987 women with singleton pregnancy who underwent cFTS. Propensity score stratification was used to assess the risk of fetal loss with and without invasive testing. Analyses were performed between 3 and 21 days after cFTS for CVS and between 28 and 42 days after cFTS for AC. Results are reported as average risk differences with 95% CIs.

RESULTS: The risks of miscarriage and stillbirth were not higher in women exposed to CVS or AC compared with unexposed women, independent of the analysis time-point. The average effect of CVS on risk of miscarriage was -0.08% (95% CI, -0.64; 0.47) at 3 days and -0.21% (95% CI, -0.58; 0.15) at 21 days after cFTS, while the effect on risk of stillbirth was -0.18% (95% CI, -0.50; 0.13) at 3 days and -0.27% (95% CI, -0.58; 0.04) at 21 days after cFTS. Regarding the effect of AC on risk of miscarriage, the analysis at 28 days after cFTS showed an average effect of 0.56% (95% CI, -0.21; 1.33), while the effect on risk of stillbirth was 0.09% (95% CI, -0.39; 0.58) at 42 days after cFTS.

CONCLUSION: Neither CVS nor AC was associated with increased risk of miscarriage or stillbirth. These findings indicate that the procedure-related risk of CVS and AC is very low. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

OriginalsprogEngelsk
TidsskriftUltrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology
Vol/bind47
Udgave nummer1
Sider (fra-til)38-44
Antal sider7
ISSN0960-7692
DOI
StatusUdgivet - jan. 2016

ID: 45971406