TY - JOUR
T1 - Risk factors and the effect of cardiac resynchronization therapy on cardiac and non-cardiac mortality in MADIT-CRT
AU - Perkiomaki, Juha S
AU - Ruwald, Anne-Christine
AU - Kutyifa, Valentina
AU - Ruwald, Martin H
AU - Mcnitt, Scott
AU - Polonsky, Bronislava
AU - Goldstein, Robert E
AU - Haigney, Mark C
AU - Krone, Ronald J
AU - Zareba, Wojciech
AU - Moss, Arthur J
AU - MADIT-CRT Investigators
N1 - Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: [email protected].
PY - 2015/12
Y1 - 2015/12
N2 - AIMS: To understand modes of death and factors associated with the risk for cardiac and non-cardiac deaths in patients with cardiac resynchronization therapy with implantable cardioverter-defibrillator (CRT-D) vs. implantable cardioverter-defibrillator (ICD) therapy, which may help clarify the action and limitations of cardiac resynchronization therapy (CRT) in relieving myocardial dysfunction.METHODS AND RESULTS: In Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT), during 4 years of follow-up, 169 (9.3%) of 1820 patients died of known causes, 108 (63.9%) deemed cardiac, and 61 (36.1%) non-cardiac. In multivariate analysis, increased baseline creatinine was significantly associated with both cardiac and non-cardiac deaths [hazard ratio (HR) 2.97, P < 0.001; HR 1.80, P = 0.035, respectively], as was diabetes (HR 1.79, P = 0.006; HR 1.73, P = 0.038, respectively), and the worst New York Heart Association Class > II more than 3 months prior to enrolment (HR 1.90, P = 0.012; HR 2.46, P = 0.010, respectively). Baseline left atrial volume index was significantly associated only with cardiac mortality (HR 1.28 per 5 unit increase, P < 0.001). Ischaemic cardiomyopathy was associated only with non-cardiac death (HR 3.54, P = 0.001). CRT-D vs. an ICD-only was associated with a reduced risk for cardiac death in patients with left bundle branch block (LBBB) (HR 0.56, P = 0.029) but was associated with an increased risk for non-cardiac death in non-LBBB patients (HR 3.48, P = 0.048).CONCLUSIONS: In MADIT-CRT, two-thirds of the deaths were cardiac and one-third non-cardiac. Many of the same risk factors were associated with both cardiac and non-cardiac mortalities. CRT-D was associated with a reduced risk for cardiac death in LBBB but an increased risk for non-cardiac death in non-LBBB.CLINICAL TRIAL REGISTRATION: Information for the MADIT-CRT main study http://www.clinicaltrials.gov, NCT00180271.
AB - AIMS: To understand modes of death and factors associated with the risk for cardiac and non-cardiac deaths in patients with cardiac resynchronization therapy with implantable cardioverter-defibrillator (CRT-D) vs. implantable cardioverter-defibrillator (ICD) therapy, which may help clarify the action and limitations of cardiac resynchronization therapy (CRT) in relieving myocardial dysfunction.METHODS AND RESULTS: In Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT), during 4 years of follow-up, 169 (9.3%) of 1820 patients died of known causes, 108 (63.9%) deemed cardiac, and 61 (36.1%) non-cardiac. In multivariate analysis, increased baseline creatinine was significantly associated with both cardiac and non-cardiac deaths [hazard ratio (HR) 2.97, P < 0.001; HR 1.80, P = 0.035, respectively], as was diabetes (HR 1.79, P = 0.006; HR 1.73, P = 0.038, respectively), and the worst New York Heart Association Class > II more than 3 months prior to enrolment (HR 1.90, P = 0.012; HR 2.46, P = 0.010, respectively). Baseline left atrial volume index was significantly associated only with cardiac mortality (HR 1.28 per 5 unit increase, P < 0.001). Ischaemic cardiomyopathy was associated only with non-cardiac death (HR 3.54, P = 0.001). CRT-D vs. an ICD-only was associated with a reduced risk for cardiac death in patients with left bundle branch block (LBBB) (HR 0.56, P = 0.029) but was associated with an increased risk for non-cardiac death in non-LBBB patients (HR 3.48, P = 0.048).CONCLUSIONS: In MADIT-CRT, two-thirds of the deaths were cardiac and one-third non-cardiac. Many of the same risk factors were associated with both cardiac and non-cardiac mortalities. CRT-D was associated with a reduced risk for cardiac death in LBBB but an increased risk for non-cardiac death in non-LBBB.CLINICAL TRIAL REGISTRATION: Information for the MADIT-CRT main study http://www.clinicaltrials.gov, NCT00180271.
U2 - 10.1093/europace/euv201
DO - 10.1093/europace/euv201
M3 - Journal article
C2 - 26071234
SN - 1099-5129
VL - 17
SP - 1816
EP - 1822
JO - Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
JF - Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
IS - 12
ER -