Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Retinal layer segmentation in rodent OCT images: Local intensity profiles & fully convolutional neural networks

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Integrated model of insulin and glucose kinetics describing both hepatic glucose and pancreatic insulin regulation

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Digital questionnaire platform in the Danish Blood Donor Study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. BCI using imaginary movements: the simulator

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. 3D image-guided treatment planning for Ruthenium-106 brachytherapy of choroidal melanomas

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  2. Progression Over 5 Years of Prelaminar Hyperreflective Lines to Optic Disc Drusen in the Copenhagen Child Cohort 2000 Eye Study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Migration of an outer retinal element in a healthy child followed by longitudinal multimodal imaging

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

BACKGROUND AND OBJECTIVE: Optical coherence tomography (OCT) is a useful technique to monitor retinal layer state both in humans and animal models. Automated OCT analysis in rats is of great relevance to study possible toxic effect of drugs and other treatments before human trials. In this paper, two different approaches to detect the most significant retinal layers in a rat OCT image are presented.

METHODS: One approach is based on a combination of local horizontal intensity profiles along with a new proposed variant of watershed transformation and the other is built upon an encoder-decoder convolutional network architecture.

RESULTS: After a wide validation, an averaged absolute distance error of 3.77 ± 2.59 and 1.90 ± 0.91 µm is achieved by both approaches, respectively, on a batch of the rat OCT database. After a second test of the deep-learning-based method using an unseen batch of the database, an averaged absolute distance error of 2.67 ± 1.25 µm is obtained. The rat OCT database used in this paper is made publicly available to facilitate further comparisons.

CONCLUSIONS: Based on the obtained results, it was demonstrated the competitiveness of the first approach since outperforms the commercial Insight image segmentation software (Phoenix Research Labs) as well as its utility to generate labelled images for validation purposes speeding significantly up the ground truth generation process. Regarding the second approach, the deep-learning-based method improves the results achieved by the more conventional method and also by other state-of-the-art techniques. In addition, it was verified that the results of the proposed network can be generalized to new rat OCT images.