Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Retention and variability of hydrogen (H2) samples stored in plastic syringes

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Transcerebral exchange kinetics of large neutral amino acids during acute inspiratory hypoxia in humans

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Platelet function in lung cancer patients undergoing lobectomy

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Resting heart rate and mortality in the very old

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Platelet increment is not associated with endothelial damage in haematological patients: a prospective observational study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. Change in HbA1c concentration as decision parameter for frequency of HbA1c measurement

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. The association of celiac disease and allergic disease in a general adult population

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. A low-gluten diet induces changes in the intestinal microbiome of healthy Danish adults

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. The distribution of HLA DQ2 and DQ8 haplotypes and their association with health indicators in a general Danish population

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Chenodeoxycholic acid stimulated fibroblast growth factor 19 response - a potential biochemical test for bile acid diarrhoea

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer
The utility of two brands of 20 ml plastic syringes for storage of hydrogen (H2) samples as obtained in H2 breath tests were studied. Plastipak syringes were found to be significantly better with regard to the stability of the H2 concentration and the variability between the H2 samples. Storage of the H2 samples in Plastipak syringes at 5 degrees C significantly improved the H2 retention, whereas refrigeration of H2 samples stored in Once syringes did not reduce H2 loss. Storage of H2 samples in refrigerated plastic syringes is efficient and reliable for several days if syringes with minimal sample variation are used.
OriginalsprogEngelsk
TidsskriftScandinavian Journal of Clinical & Laboratory Investigation
Vol/bind47
Udgave nummer6
Sider (fra-til)627-9
Antal sider3
ISSN0036-5513
StatusUdgivet - okt. 1987