Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Reliability of cerebral autoregulation using different measures of perfusion pressure in patients with subarachnoid hemorrhage

Publikation: Bidrag til tidsskriftTidsskriftartikelpeer review

DOI

  1. Cholestasis alters brain lipid and bile acid composition and compromises motor function in neonatal piglets

    Publikation: Bidrag til tidsskriftTidsskriftartikelpeer review

  2. Effect of angiotensin-converting enzyme inhibition on cardiovascular adaptation to exercise training

    Publikation: Bidrag til tidsskriftTidsskriftartikelpeer review

  3. Gravity and lymphodynamics

    Publikation: Bidrag til tidsskriftTidsskriftartikelpeer review

  4. Changes in P2Y6 receptor-mediated vasoreactivity following focal and global ischemia

    Publikation: Bidrag til tidsskriftTidsskriftartikelpeer review

Vis graf over relationer

Dynamic cerebral autoregulation to spontaneous fluctuations in cerebral perfusion pressure (CPP) is often assessed by transcranial Doppler (TCD) in the time domain, yielding primarily the mean flow index (Mx), or in the frequency domain using transfer function analysis (TFA), yielding gain and phase. For both domains, the measurement of blood pressure is critical. This study assessed the inter-method reliability of dynamic cerebral autoregulation using three different methods of pressure measurement. In 39 patients with aneurysmal subarachnoid hemorrhage, non-invasive arterial blood pressure (ABP), invasive ABP (measured in the radial artery) and CPP were recorded simultaneously with TCD. Intraclass correlation coefficient (ICC) was used to quantify reliability. Mx was higher when calculated using invasive ABP (0.39; 95% confidence interval [95% CI]: 0.33; 0.44) compared to non-invasive ABP, and CPP. The overall ICC showed poor to good reliability (0.65; 95% CI: 0.11; 0.84; n = 69). In the low frequency domain, the comparison between invasively measured ABP and CPP showed good to excellent (normalized gain, ICC: 0.87, 95CI: 0.81; 0.91; n = 96; non-normalized gain: 0.89, 95% CI: 0.84; 0.92; n = 96) and moderate to good reliability (phase, ICC: 0.69, 95% CI: 0.55; 0.79; n = 96), respectively. Different methods for pressure measurement in the assessment of dynamic cerebral autoregulation yield different results and cannot be used interchangeably.

OriginalsprogEngelsk
Artikelnummere15203
TidsskriftPhysiological Reports
Vol/bind10
Udgave nummer6
Sider (fra-til)e15203
ISSN2051-817X
DOI
StatusUdgivet - mar. 2022

Bibliografisk note

© 2022 The Authors. Physiological Reports published by Wiley Periodicals LLC on behalf of The Physiological Society and the American Physiological Society.

ID: 75904903