Abstract
Anastomotic dehiscence remains an important challenge for colorectal surgeons worldwide. Extensive research focused on performing a safe anastomosis is conducted with rats being the most used model when examining colorectal anastomoses. In daily clinical practice resorbable sutures are used when hand-sewn anastomoses are performed. However, in the experimental studies examining colorectal anastomoses, non-resorbable sutures have predominantly been used. The aim of this study was to compare a rapidly resorbable suture with a non-resorbable suture in experimental colorectal anastomoses.
| Originalsprog | Engelsk |
|---|---|
| Tidsskrift | International Journal of Surgery |
| Vol/bind | 9 |
| Udgave nummer | 4 |
| Sider (fra-til) | 332-4 |
| Antal sider | 3 |
| ISSN | 1743-9191 |
| DOI | |
| Status | Udgivet - 2011 |