Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Quantification of cerebral perfusion and cerebrovascular reserve using Turbo-QUASAR arterial spin labeling MRI

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. ActiveAxADD: Toward non-parametric and orientationally invariant axon diameter distribution mapping using PGSE

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Coil profile estimation strategies for parallel imaging with hyperpolarized 13 C MRI

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Gamma-aminobutyric acid edited echo-planar spectroscopic imaging (EPSI) with MEGA-sLASER at 7T

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Cerebral Oxygen Metabolism in Adults with Sickle Cell Disease

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. European Ultrahigh-Field Imaging Network for Neurodegenerative Diseases (EUFIND)

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Prospective motion correction in single voxel spectroscopy at 7T using fat navigators and higher order shimming

    Publikation: KonferencebidragKonferenceabstrakt til konferenceForskningpeer review

  • Moss Y Zhao
  • Lena Václavů
  • Esben T Petersen
  • Bart J Biemond
  • Magdalena J Sokolska
  • Yuriko Suzuki
  • David L Thomas
  • Aart J Nederveen
  • Michael A Chappell
Vis graf over relationer

PURPOSE: To compare cerebral blood flow (CBF) and cerebrovascular reserve (CVR) quantification from Turbo-QUASAR (quantitative signal targeting with alternating radiofrequency labeling of arterial regions) arterial spin labeling (ASL) and single post-labeling delay pseudo-continuous ASL (PCASL).

METHODS: A model-based method was developed to quantify CBF and arterial transit time (ATT) from Turbo-QUASAR, including a correction for magnetization transfer effects caused by the repeated labeling pulses. Simulations were performed to assess the accuracy of the model-based method. Data from an in vivo experiment conducted on a healthy cohort were retrospectively analyzed to compare the CBF and CVR (induced by acetazolamide) measurement from Turbo-QUASAR and PCASL on the basis of global and regional differences. The quality of the two ASL data sets was examined using the coefficient of variation (CoV).

RESULTS: The model-based method for Turbo-QUASAR was accurate for CBF estimation (relative error was 8% for signal-to-noise ratio = 5) in simulations if the bolus duration was known. In the in vivo experiment, the mean global CVR estimated by Turbo-QUASAR and PCASL was between 63% and 64% and not significantly different. Although global CBF values of the two ASL techniques were not significantly different, regional CBF differences were found in deep gray matter in both pre- and postacetazolamide conditions. The CoV of Turbo-QUASAR data was significantly higher than PCASL.

CONCLUSION: Both ASL techniques were effective for quantifying CBF and CVR, despite the regional differences observed. Although CBF estimated from Turbo-QUASAR demonstrated a higher variability than PCASL, Turbo-QUASAR offers the advantage of being able to measure and control for variation in ATT.

OriginalsprogEngelsk
TidsskriftMagnetic Resonance in Medicine
Vol/bind83
Udgave nummer2
Sider (fra-til)731-748
Antal sider18
ISSN0740-3194
DOI
StatusUdgivet - feb. 2020

Bibliografisk note

© 2019 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

ID: 57934425