TY - JOUR
T1 - Quantification of 1,N6-etheno-2'-deoxyadenosine in human urine by column-switching LC/APCI-MS/MS
AU - Hillestrøm, Peter R
AU - Hoberg, Anne-Mette
AU - Weimann, Allan
AU - Poulsen, Henrik E
PY - 2004/6/1
Y1 - 2004/6/1
N2 - 1,N6-etheno-2'-deoxyadenosine (epsilondA) is one of several promutagenic DNA modifications arising from cellular oxidative metabolism. It is believed that these background DNA lesions may contribute to various diseases, such as cancer. Therefore, human biomonitoring of epsilondA in urine could be a potential marker for oxidative stress-related DNA damage. Existing methods for quantifying urinary epsilondA use 32P postlabeling. We have developed a nonradioactive, fast, and easier method based on column-switching liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry (LC/APCI-MS/MS) in the positive mode. Differences in column temperatures were used to influence analyte retention and sample focusing. With multiple reaction monitoring (MRM) mode the afforded limit of detection was about 0.7 pM when starting with 3 ml of urine. The urinary excretion rates of epsilondA from 28 nonsmoking and 5 smoking men were 10.0-99.6 pmol/24 h, and did not correlate with body weight, age, or plasma vitamin C concentration. The 5 smokers excreted 30.5 +/-8.5 and the 28 nonsmokers excreted 38.6 +/- 2.4 pmol epsilondA per 24 h, p=.37 (mean +/- SEM). The demonstrated level of performance suggests the future applicability of this method to studies of cancer and other diseases related to oxidative stress in humans.
AB - 1,N6-etheno-2'-deoxyadenosine (epsilondA) is one of several promutagenic DNA modifications arising from cellular oxidative metabolism. It is believed that these background DNA lesions may contribute to various diseases, such as cancer. Therefore, human biomonitoring of epsilondA in urine could be a potential marker for oxidative stress-related DNA damage. Existing methods for quantifying urinary epsilondA use 32P postlabeling. We have developed a nonradioactive, fast, and easier method based on column-switching liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry (LC/APCI-MS/MS) in the positive mode. Differences in column temperatures were used to influence analyte retention and sample focusing. With multiple reaction monitoring (MRM) mode the afforded limit of detection was about 0.7 pM when starting with 3 ml of urine. The urinary excretion rates of epsilondA from 28 nonsmoking and 5 smoking men were 10.0-99.6 pmol/24 h, and did not correlate with body weight, age, or plasma vitamin C concentration. The 5 smokers excreted 30.5 +/-8.5 and the 28 nonsmokers excreted 38.6 +/- 2.4 pmol epsilondA per 24 h, p=.37 (mean +/- SEM). The demonstrated level of performance suggests the future applicability of this method to studies of cancer and other diseases related to oxidative stress in humans.
KW - Chromatography, Liquid/instrumentation
KW - Deoxyadenosines/urine
KW - Humans
KW - Reproducibility of Results
KW - Spectrometry, Mass, Electrospray Ionization/methods
U2 - 10.1016/j.freeradbiomed.2004.02.068
DO - 10.1016/j.freeradbiomed.2004.02.068
M3 - Journal article
C2 - 15135174
SN - 0891-5849
VL - 36
SP - 1383
EP - 1392
JO - Free Radical Biology & Medicine
JF - Free Radical Biology & Medicine
IS - 11
ER -