N2 - Validation of in vitro test systems using the modular approach with steps addressing reliability and relevance is an important aim when developing in vitro tests in e.g. reproductive toxicology. The ex vivo human placental perfusion system may be used for such validation, here presenting the placental perfusion model in Copenhagen including control substances. The positive control substance antipyrine shows no difference in transport regardless of perfusion media used or of terms of delivery (n=59, p
AB - Validation of in vitro test systems using the modular approach with steps addressing reliability and relevance is an important aim when developing in vitro tests in e.g. reproductive toxicology. The ex vivo human placental perfusion system may be used for such validation, here presenting the placental perfusion model in Copenhagen including control substances. The positive control substance antipyrine shows no difference in transport regardless of perfusion media used or of terms of delivery (n=59, p