Pulse contour-derived cardiac output in hemodialysis patients

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Increased risk of Staphylococcus aureus bacteremia in hemodialysis-A nationwide study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Treatment of a soft tissue calcification in a patient receiving peritoneal dialysis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Chronic obstructive pulmonary disease in patients with end-stage kidney disease on hemodialysis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Home hemodialysis: infrastructure, water, and machines in the home

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Impact of extracorporeal blood flow rate on blood pressure, pulse rate and cardiac output during haemodialysis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Right ventricular failure after implantation of a continuous-flow left ventricular assist device: early haemodynamic predictors

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Potassium dynamics are attenuated in hyperkalemia and a determinant of QT adaptation in exercising hemodialysis patients

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Blood flow measurements during hemodialysis vascular access interventions - Catheter-based thermodilution or Doppler ultrasound?

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer
Reliable methods for cardiac output determination are essential for studying the pathophysiology of intradialytic hypotension. Use of the current gold standard, the Transonic monitor, requires an arteriovenous fistula. We wished to verify the accuracy of a method based on finger pulse contour analysis, namely the Finometer monitor (FNM) for further use on patients dialyzing on a central vascular catheter. Fifty simultaneous cardiac output measurements were obtained during hemodialysis sessions in 25 patients. The internal variability of the FNM measurements was assessed by comparing 24 pairs of immediately successive measurements. The variability of successive FNM measurements was small (bias 0.28%, SD +/- 6.1%; NS). The absolute cardiac output values reported by the FNM were unreliable (bias 20.1%, SD +/- 35.3%; P
OriginalsprogEngelsk
TidsskriftHemodialysis International
Vol/bind14
Udgave nummer1
Sider (fra-til)78-83
Antal sider6
ISSN1492-7535
DOI
StatusUdgivet - 1 jan. 2010

ID: 31012479