Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Placement of a fine-bore rectal balloon catheter in the anal canal does not affect anal sphincter pressures: improving our understanding of physiological function with anal acoustic reflectometry

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Accuracy of preoperative staging with multidetector computed tomography in colon cancer

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. A novel method for measurement of the recto-anal inhibitory reflex using anal acoustic reflectometry

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Surgical repair of parastomal bulging: a retrospective register-based study on prospectively collected data

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Letter to the editor: "Update in native tissue vaginal vault prolapse repair"

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. A novel method for measurement of the recto-anal inhibitory reflex using anal acoustic reflectometry

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Evaluation of suture material used in anterior colporrhaphy and the risk of recurrence

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Validity of bladder volume measurement by ultrasound in women postpartum

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

AIM: The recto-anal inhibitory reflex (RAIR) is currently measured using anorectal manometry catheters, which may distort the anal canal. Anal acoustic reflectometry (AAR) is considered a catheter-free technique for evaluating the physiological function of the anal canal; however, it has yet to be used to elicit the RAIR. For the RAIR to be measured with AAR, the effect of placing an additional rectal balloon catheter on the measured AAR parameters needs to be investigated: that is the aim of this work.

METHOD: Patients aged over 18 years attending hospital for the investigation of pelvic floor disorders were included. AAR parameters were obtained before and after a rectal balloon catheter was placed alongside the AAR catheter. The following parameters were measured: opening pressure (Op, cmH2 O), opening elastance (Oe, cmH2 O/mm2 ), closing pressure (Cp, cmH2 O), closing elastance (Ce, cmH2 O/mm2 ), hysteresis (Hys, %), squeeze opening pressure (SqOp, cmH2 O) and squeeze opening elastance (SqOe, cmH2 O/mm2 ).

RESULTS: Thirty-five patients were included in the analysis, of whom 28 were women. The median age was 58 years. Comparison of median AAR parameters before and after catheter placement showed no significant difference: Op (36.36 vs 33.42, P = 0.09), Oe (1.27 vs 1.39, P = 0.19), Cp (18.62 vs 19.73, P = 0.13), Ce (1.2 vs 1.28, P = 0.33), Hys (41.08 vs 40.11, P = 0.17), SqOp (81.85 vs 81.65, P = 0.93) and SqOe (1.44 vs 1.49, P = 0.55).

DISCUSSION: Placement of a rectal balloon catheter alongside the AAR catheter has no significant effect on the measured AAR parameters. The results of this study add to the fundamental basic science and understanding of the physiological function of the anal canal.

OriginalsprogEngelsk
TidsskriftColorectal Disease
Vol/bind22
Udgave nummer11
Sider (fra-til)1626-1631
Antal sider6
ISSN1462-8910
DOI
StatusUdgivet - nov. 2020

Bibliografisk note

© 2020 The Association of Coloproctology of Great Britain and Ireland.